Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Partition coefficient

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
08 - 17 May 2003
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
Deviations:
no
Remarks:
The testing facility indicated that the protocol was followed without deviation.
Qualifier:
according to guideline
Guideline:
EU Method A.8 (Partition Coefficient)
Deviations:
no
Remarks:
The testing facility indicated that the protocol was followed without deviation.
GLP compliance:
yes (incl. QA statement)
Type of method:
HPLC method
Partition coefficient type:
octanol-water
Specific details on test material used for the study:
- Batch n°: 00403487
- Analytical purity: > 98%
- Expiration date: 31 December 2003
- Storage condition: at room temperature
Analytical method:
high-performance liquid chromatography
Key result
Type:
log Pow
Partition coefficient:
3.9
Temp.:
25 °C
Remarks on result:
other: The pH was not mentioned in the report
Details on results:
The T002615 solution was injected three times and the combined reference item solution was injected six times. The thiourea solution was injected three times. The log Pow was calculated using a regression curve (log k' vs. logPow) and was found to be 3.9.

Results

The chromatography of the test item showed one sharp main peak with a well-defined and reproducible retention time. The HPLC method was therefore considered to be suitable for the purpose of the study. Based on the chromatographic data, T002615 was considered to be stable during the test procedure.

The retention times of the individual measurements of the reference items, the test item andfor the determination of the dead time are given in Table 1. The mean retention times and the derived capacity factors are stated in Table 2. Using the corresponding log Pow values of the reference items from the OECD guideline, the regression coefficients were calculated as stated in Table 2. The log Pow value of the test item was calculated from the calibration equation.

Table 1:    Retention times in minutes of the reference items and the test item

 

 

I.Run

2.Run

3.Run

4.Run

5.Run

6.Run

Thiourea(= dead time)

1.898

1.901

1.899

 

Reference Items

Nitrobenzene

3.591

3.589

3.588

3.591

 3.586

3.588

Bromobenzene

6.042

6.043

6.040

6.045

6.034

6.043

Isopropylbenzene

8.651

8.651

8.645

8.655

8.644

8.654

1,2,4-Trichlorobenzene

11.000

11.000

10.993

11.008

11.001

11.009

Fluoranthene

15.651

15.661

15.648

15.683

15.692

15.706

2,4-DDT

28.240

28.236

28.213

28.259

28.254

28.200

Test Item

T002615

9.073

9.061

9.068

 


Table 2:     Results of Linear Regression of Log k'vs.Log Pow

 

 

Number

Mean

k'

logk'

logPow

 

of

retention

 

 

 

 

analysis

time [min]

 

 

 

Thiourea(= dead time)

3

1.90

-

-

-

Reference Items:

Nitrobenzene

6

3.59

0.89

-0.05

1.9

Bromobenzene

6

6.04

2.18

0.34

3.0

Isopropylbenzene

6

8.65

3.55

0.55

3.7

1,2,4-Trichlorobenzene

6

11.00

4.79

0.68

4.2

Fluoranthene

6

15.67

7.25

0.86

4.7

2,4-DDT

6

28.23

13.87

1.14

6.2

 

slope =

 

 

0.279

Linear Regression:

y-axis intercept =

 

 

-0.516

 

coefficient ofregres

sion=

 

0.991

Table 3:                Result of T002615 analyses

 

Number

of analyses

Retention time [min]

k'

logk'

logPow

Mean logPow

1

2

3

9.07

9.06

9.07

3.78

3.77

3.77

0.57714

0.5764129 0.5768372

3.9

3.9

3.9

3.9

The tabulated values represent rounded results, which were obtained by calculation using the exact raw data.

 

Conclusions:
In conclusion, using the HPLC method, the n-octanol/water partition coefficient of T002615 was determined to be log Pow=3.9 at 25 deg C.

Description of key information

The partition coefficient of T002615 was determined in a GLP study performed according to OECD Guideline 117 and EU Method A.8 (Klimisch 1, Tognucci, 2003).

The HPLC method was applied for the determination of the partition coefficient (Pow). The n-octanol/water partition coefficient of T002615 was determined to be log Pow=3.9 at 25°C.

Key value for chemical safety assessment

Log Kow (Log Pow):
3.9
at the temperature of:
25 °C

Additional information