Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
eye irritation: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018-04-04
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 437 (Bovine Corneal Opacity and Permeability Test Method for Identifying i) Chemicals Inducing Serious Eye Damage and ii) Chemicals Not Requiring Classification for Eye Irritation or Serious Eye Damage)
Version / remarks:
2017-10-09
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
signed 2015-06-05

Test material

Constituent 1
Chemical structure
Reference substance name:
Potassium neodecanoate
EC Number:
247-978-7
EC Name:
Potassium neodecanoate
Cas Number:
26761-42-2
Molecular formula:
C10H19KO2
IUPAC Name:
potassium 2-methylnonanoate
Test material form:
solid
Details on test material:
- State of aggregation: solid
Specific details on test material used for the study:
STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: dry and cool

Test animals / tissue source

Details on test animals or tissues and environmental conditions:
SOURCE OF COLLECTED EYES
- Source: abattoir A. Moksel AG, Buchloe, Germany
- Characteristics of donor animals: cattle was between 17 and 20 months old.
- Storage, temperature and transport conditions of ocular tissue: fresh eyes were collected from the slaughterhouse and were transported in HBSS containing Pen/Strep on ice to the laboratories
- Time interval prior to initiating testing: immediately after arrival of the eyes, cornea preparation was initiated and was used for BCOP testing on the same day.

Test system

Vehicle:
physiological saline
Remarks:
0.9 % NaCl
Controls:
yes, concurrent positive control
yes, concurrent negative control
Amount / concentration applied:
TEST MATERIAL
- Amount(s) applied (volume or weight with unit): 750 μL of the test item preparation
- Concentration (if solution): 10 % w/v concentration
Duration of treatment / exposure:
10 minutes
Observation period (in vivo):
not applicable
Duration of post- treatment incubation (in vitro):
2 hours
Number of animals or in vitro replicates:
Number of bovine corneae per dose:
Test item: triplicates
Negative control: triplicates
Positive control: triplicates
Details on study design:
SELECTION AND PREPARATION OF CORNEAS
- eyes were examined for defects and any defective eyes were discarded. Eyes with scratches or any kind of opacity were not used.
- tissue surrounding the eyeball was pulled away and the cornea was excised.
- isolated corneas were stored in a petri dish containing HBSS. Before the corneas were mounted in corneal holders (BASF, Duratec) with the endothelial side against the O-ring of the posterior chamber, they had been visually examined for defects and any defective cornea had been discarded. The anterior chamber was then positioned on top of the cornea and tightened with screws. The chambers of the corneal holder were then filled with pre-warmed RPMI (without phenol red) containing 1% FBS and 2 mM L-glutamine (complete RPMI).
- corneas were incubated for one hour at 32 ± 1 °C for equilibration in an air incubator.

QUALITY CHECK OF THE ISOLATED CORNEAS
- after the equilibration period, the medium was removed from both chambers and replaced with fresh complete RPMI.
- an initial measurement was performed on each of the corneas using the opacitometer.
- three corneas with illuminance readings approximately equivalent to the median illuminance of all corneas were selected as negative-control corneas.
- the illuminance of each cornea was read and recorded.
- only corneas that had an initial illuminance reading I > I0/1.1651 lux (an equivalent to the opacity threshold of 7 as listed in OECD 437) were used for the assay.

APPLICATION DOSE AND EXPOSURE TIME
- medium was removed from the anterior chamber and replaced with the test item or control.
- 750 μL of the test item preparation or the control substance was introduced into the anterior chamber (closed-chamber method).
- after 10 minutes incubation at 32 ± 1 °C either the test substance or the control substance was removed.

REMOVAL OF TEST SUBSTANCE/CONTROL SUBSTANCES
- epithelium was washed at least three times with MEM (containing phenol red).
- once the medium was free of test substance, the cornea was finally rinsed with complete RPMI (without phenol red).

METHODS FOR MEASURED ENDPOINTS:
- anterior chamber was refilled with complete RPMI and an illuminance measurement was performed after 2 hours incubation at 32 ± 1 °C.
- each cornea was observed visually and pertinent observations were recorded.
- corneas were visually examined for tissue peeling, residual test chemical and non-uniform opacity patterns and observation were recorded.
- after the illuminance measurement was performed, the medium was removed from both chambers of the holder.
- posterior chamber was refilled with fresh complete RPMI.
- 1 mL of a 4 mg/mL sodium fluorescein solution was added to the anterior chamber and the corneas were incubated for 90 minutes at 32 ± 1 °C.
- then the medium from the posterior chamber was removed and its optical density at 490 nm (OD490) was determined, using a spectrophotometer (Jenway 6405 UV/VIS).

Evaluation of the opacity:
- the following formula was used to calculate the opacity, whereas the values a and b are equipment-specific variables empirically determined by the manufacturer:
Opacity = ((I0/I) - b)/ a
with a = 0.025 and b = 0.9894
- value I0 is the illuminance through a holder without cornea, but with windows and liquid. This value is determined by taking the mean for a set of cornea holders and is reevaluated annually. This I0 value is than calculated to the respective data of the opacitometer and the data according to guideline (opacity < 7). So the initial illuminance can be calculated and corneas below this value will be discarded.
- change in opacity for each cornea was calculated by subtracting the initial opacity reading from the final opacity reading. These values were corrected by subtracting from each the average change in opacity observed for the negative-control corneas. The mean opacity value for each treatment was calculated by averaging the corrected opacity values of each cornea for a given treatment.

Evaluation of the permeability:
- mean OD490 for the blank cuvettes was calculated.
- mean blank OD490 was subtracted from the OD490 of each cuvette (corrected OD490).
- any dilutions that were made to bring the OD490 values into the linear range of the spectrophotometer (OD490 should be less than 1.500), were taken into account by multiplying the OD490 value of the dilution by the dilution factor.
- final-corrected OD490 of the test article and the positive control were calculated by subtracting the average-corrected OD490 of the negative-control corneas from the corrected OD490 value of each treated cornea:
Final-corrected OD490 = (OD490 – mean blank OD490) – average-corrected negative control OD490
- mean OD490 value of each treatment group was calculated by averaging the final corrected OD490 values of the treated corneas for that treatment condition.

SCORING SYSTEM: In Vitro Irritancy Score (IVIS)
The following formula was used to determine the in vitro irritation score (IVIS):
IVIS = mean opacity value + (15 x mean permeability OD490 value)
For the IVIS cut-off values for identifying test substances as inducing serious eye damage and test substances not including eye irritation or serious eye damage please refer to table 1 in the field "Any other information onmaterial and methods incl. tables" below.

ACCEPTABILITY CRITERIA
- the BCOP assay is considered to be valid if the in vitro irritation score obtained with the positive control falls within the two standard deviations of the current historical mean.
- the negative control responses should result in opacity and permeability values that are less than the established upper limits for background bovine corneas treated with the respective negative control.

Results and discussion

In vitro

Results
Irritation parameter:
in vitro irritation score
Remarks:
(mean)
Value:
81.34
Vehicle controls validity:
not examined
Negative controls validity:
valid
Positive controls validity:
valid
Other effects / acceptance of results:
All 3 corneas treated with potassium neodecanoate showed complete opacity of the tissue.

ACCEPTANCE OF RESULTS:
- Acceptance criteria met for negative control: the negative control responses resulted in opacity and permeability values that are less than the established upper limits for background bovine corneas treated with the respective negative control.
- Acceptance criteria met for positive control: the in vitro irritation score obtained with the positive control fell within the two standard deviations of the current historical mean and therefore this assay is considered to be valid.

The evaluation of acceptability criteria was performed by using the following historical data:
- for evaluation of the validity of the positive control, the historical mean IVIS score as obtained from 2015 until 2018 was used (please refer to the tables in the field "Any other information on results incl. tables").
- for the evaluation of the validity of the negative control, the historical upper limits of the opacity and permeability values as obtained in 2017 and 2018 were used (please refer to the tables in the field "Any other information on results incl. tables" below)

Please also refer for results to the field "Any other information on results incl. tables" below

Any other information on results incl. tables

Table 1: Opacity

Cornea No.

Test Item

Initial Opacity

Final Opacity

Change of Opacity Value

Corrected Opacity Value

1

Negative Control

1.11

1.61

0.50

 

2

1.11

1.87

0.75

 

3

1.11

2.16

1.05

 

MV

1.11

1.88

0.77

 

4

 

Positive Control

3.19

34.99

31.80

31.03

5

2.16

29.80

27.64

26.87

6

2.27

29.49

27.22

26.45

MV

2.54

31.43

28.89

28.12

7

 

Test Item

0.02

42.86

42.84

42.08

8

0.19

46.18

46.00

45.23

9

1.61

48.94

47.33

46.56

MV

0.61

46.00

45.39

44.62

MV = mean value

Table 2: Permeability

Cornea No.

Test Item

OD490

Corrected OD490 Value

1

Negative Control

0.022

 

2

0.045

 

3

0.015

 

MV

0.027

 

4

 

Positive Control

0.985

0.958

5

1.166

1.139

6

0.905

0.878

MV

1.019

0.991

7

 

Test Item

2.460

2.433

8

2.390

2.363

9

2.575

2.548

MV

2.475

2.448

MV = mean value

Table 3: In vitro irritation score

Cornea No.

Test Item

Corrected Opacity

Corrected OD490 Value

IVIS

1

Negative Control

0.50

0.022

 

2

0.75

0.045

 

3

1.05

0.015

 

MV

0.77

0.027

1.18

4

 

Positive Control

31.03

0.958

 

5

26.87

1.139

 

6

26.45

0.878

 

MV

28.12

0.991

42.99

7

 

Test Item

42.08

2.433

 

8

45.23

2.363

 

9

46.56

2.548

 

MV

44.62

2.448

81.34

MV = mean value

Table 4: Historical mean in vitro irritation score of the positive control from February 2015 until April 2018

 

IVIS Positive Control – Ethanol 100%

Mean Value (MV)

48.57

Standard Deviation (SP)

9.69

MV-2xSD

29.20

MV+2xSD

67.94

Number of Replicates providing Historical Mean: 50

Positive controls are updated after every single experiment or at least every 3 months

Table 5: Historical data on opacity and permeability of the positive control (Ethanol 100 %) from August 2017 until April 2018

Number of Replicates

Providing Historical

Mean

Opacity

Permeability

IVIS

Change of

Opacity Value

Corrected

Opacity Value

OD490 Value

Corrected

OD490 Value

 

1

37.495

37.899

1.013

1.004             

53.36

27.335

27.739

1.147

1.138

30.218

30.622

2.120

2.111

2

24.492

23.921

1.442

1.436

49.70

31.754

31.182

1.108

1.102

30.259

29.688

1.755

1.749

3

40.460

39.546

1.270

1.266

49.84

28.925

28.010

0.949

0.945

29.064

28.149

1.381

1.377

4

22.710

22.292

1.182

1.178

52.16

35.986

35.567

1.780

1.776

24.036

23.618

2.050

2.046

5

25.61

24.97

2.025

2.014

63.38

28.89

28.25

2.920

2.909

27.82

27.18

2.405

2.394

6

22.66

21.94

1.407

1.399

42.08

22.03

21.31

1.354

1.346

22.31

21.60

1.355

1.347

7

31.80

31.03

0.985

0.958

42.99

27.64

26.87

1.166

1.139

27.22

26.45

0.905

0.878

Mean Value (MV)

28.511

27.993

1.510

1.501

50.50

Standard Deviation (SD

5.022

5.109

0.534

0.536

7.13

MV- 2xSD

18.467

17.774

0.442

0.429

36.24

MV+2xSD

38.555

38.212

2.579

2.573

64.77

Table 6: Historical mean in vitro irritation score of the negative control from February 2015 until April 2018

 

IVIS Negative Control – NaCl 0.9 %

Mean Value (MV)

0.81

Standard Deviation (SD)

0.64

MV-2xSD

-0.48

MV+2xSD

2.09

Number of Replicates providing Historical Mean: 50

Negative controls are updated every single experiment or at least every 3 months

Table 7: Historical data on opacity and permeability of the negative control (NaCl 0.9 %) from August 2017 until April 2018

Number of Replicates

Providing Historical

Mean

Opacity

Permeability

 

Change of

Opacity Value

OD490 Value

IVIS

1

-0.57

0.009

-0.27

-0.11

0.013

-0.53

0.004

2

-0.25

0.004

0.66

0.80

0.005

1.17

0.008

3

0.11

0.004

0.48

0.68

0.005

0.47

0.003

4

0.19

0.008

0.18

-0.12

0.005

0.00

0.018

5

0.11

0.005

0.81

0.74

0.022

1.06

0.007

6

0.26

0.011

0.83

1.21

0.004

0.68

0.008

7

0.50

0.022

1.18

0.75

0.045

1.05

0.015

Mean Value (MV)

0.39

0.01

0.55

Standard Deviation (SD

0.54

0.01

0.48

MV- 2xSD

-0.69

-0.01

-0.40

MV+2xSD

1.47

0.03

1.51

Applicant's summary and conclusion

Interpretation of results:
Category 1 (irreversible effects on the eye) based on GHS criteria
Conclusions:
According to the bovine corneal opacity and permeability assay, since the IVIS was > 55 (IVIS score: 81.34), the test item Potassium neodecanoate can be considered as requiring classification for eye irritation or serious eye damage.
According to the Regulation (EC) No 1272/2008 and subsequent adaptions, the substance is classified for serious eye damage (Category 1; H318).