Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
relative self-ignition temperature (solids)
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
other:
Cross-reference
Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016-03-01 to 2016-05-18
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
Qualifier:
according to guideline
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
GLP compliance:
yes (incl. QA statement)
Type of method:
differential scanning calorimetry
Key result
Melting / freezing pt.:
> 500 °C
Remarks on result:
other: No melting point could be determined via DSC (differential scanning calorimetry) up to a temperature of 520°C.
Remarks:
The test item changed the colour from white to grey in the pre-test.
Conclusions:
No melting point could be determined via DSC (differential scanning calorimetry) up to a temperature of 520°C.
Therefore the melting point should be stated as > 500°C.

Data source

Materials and methods

Results and discussion

Applicant's summary and conclusion