Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
24 August 2017 to 27 October 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Remarks on result:
no flash point - measurement carried out until boiling temperature

The preliminary test was stopped, because the test item started to boil (at ca 132 °C) before determination of a flash point. The preliminary test was repeated to confirm the result. As no ignition was found in both tests no further testing was performed.

Interpretation of results:
GHS criteria not met
Conclusions:
In a preliminary test the substance started to boil before determination of a flash point.

Description of key information

The substance started to boil before determination of a flash point.

Key value for chemical safety assessment

Additional information