Registration Dossier

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
explosiveness
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018
Reliability:
1 (reliable without restriction)
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
GLP compliance:
yes (incl. QA statement)
Parameter:
sensitiveness to friction: friction load (N)
Remarks on result:
not sensitive to friction using a friction load of 360 N
Parameter:
sensitiveness to impact: impact energy (J)
Remarks on result:
not sensitive to impact using an impact energy of 40 J
Parameter:
thermal sensitivity - Koenen test: limiting diameter (mm)
Remarks on result:
not thermal sensitive if heated under defined confinement
Interpretation of results:
GHS criteria not met
Conclusions:
Substance is not explosives according to A.14.

Description of key information

Substance is not explosives according to A.14.

Key value for chemical safety assessment

Explosiveness:
non explosive

Additional information

Justification for classification or non-classification