Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
22 February 2018 to 30 October 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Specific details on test material used for the study:
Physical Form: Amber liquid
Stability: Stable at room temperature
Key result
Flash point:
> 200 °C
Atm. press.:
102.5 kPa
Interpretation of results:
GHS criteria not met
Conclusions:
No flash to boiling.
Executive summary:

In a study performed to the standardised guideline EU Test Method A.9 under GLP conditions, the flash point of the test material has been determined to be >200°C as no flash to boiling.  

Description of key information

In a study performed to the standardised guideline EU Test Method A.9 under GLP conditions, the flash point of the test material has been determined to be >200°C as no flash to boiling.  

 

Key value for chemical safety assessment

Additional information