Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Justification for type of information:
Attempts were made to ignite the solid and a sample was also heated in a furnace.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
equivalent or similar to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Principles of method if other than guideline:
Attempts were made to ignite the substance
GLP compliance:
no

Test material

Constituent 1
Chemical structure
Reference substance name:
Sodium zirconium lactate
EC Number:
239-570-2
EC Name:
Sodium zirconium lactate
Cas Number:
15529-67-6
Molecular formula:
C3H6O3xZr
IUPAC Name:
Sodium zirconium lactate
Test material form:
solid
Specific details on test material used for the study:
Batch number of test material: C-07-3743

Results and discussion

Flammable solids
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

Applicant's summary and conclusion

Interpretation of results:
not classified based on GHS criteria
Conclusions:
The substance itself does not support combustion.