Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
17 March 2017
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Only a 1 page study summary, though the critical information for this endpoint is included.
Qualifier:
according to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
Deviations:
not specified
GLP compliance:
yes
Other quality assurance:
other: no data
Type of method:
Laser scattering/diffraction
Type of particle tested:
other: no data
Type of distribution:
volumetric distribution
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: KM 16033
- Expiration date of the lot/batch: No data
- Purity test date: No data

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: No data
- Stability under test conditions: No data
- Solubility and stability of the test substance in the solvent/vehicle: No data
- Reactivity of the test substance with the solvent/vehicle of the cell culture medium: No data

TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Treatment of test material prior to testing: No data
- Final dilution of a dissolved solid, stock liquid or gel: No data
- Final preparation of a solid: No data
Percentile:
D10
Mean:
254 µm
Remarks on result:
other: average of three measurements
Percentile:
D50
Mean:
673 µm
Remarks on result:
other: average of three measurements
Percentile:
D90
Mean:
1 242 µm
Remarks on result:
other: average of three measurements
Conclusions:
In a particle size distribution study with tetraammineplatinum(II) diacetate, respective d10, d50 and d90 values of 254, 673 and 1242 μm were measured.
Executive summary:

In a guideline (ISO 13320) particle size distribution study with tetraammineplatinum(II) diacetate, respective d10, d50 and d90 values of 254, 673 and 1242 μm were measured using laser diffraction.

Description of key information

In a guideline (ISO 13320) particle size distribution study with tetraammineplatinum(II) diacetate, respective d10, d50 and d90 values of 254, 673 and 1242 μm were measured using laser diffraction.

Additional information