Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
July 2020
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
study well documented, meets generally accepted scientific principles, acceptable for assessment
Principles of method if other than guideline:
Guideline followed not specified in study report.
GLP compliance:
not specified
Type of method:
rotational viscometer (dynamic)
Specific details on test material used for the study:
Lot# 5084 supplied by the Delaware River Plant
Key result
Temp.:
other: 25°C
Parameter:
other: cps
Value:
750
Conclusions:
The viscosity of Santicizer Platinum P1700 was determined to be 750 cps at 25°C.
Executive summary:

The viscosity of Santicizer Platinum P1700 was determined to be 750 cps at 25°C.

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
July 2020
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
study well documented, meets generally accepted scientific principles, acceptable for assessment
Justification for type of information:
The justification for read across is provided as an attachment in IUCLID Section 13.
Reason / purpose for cross-reference:
read-across: supporting information
Principles of method if other than guideline:
Guideline followed not specified in study report.
GLP compliance:
not specified
Type of method:
rotational viscometer (dynamic)
Specific details on test material used for the study:
Lot# not specified supplied by the Delaware River Plant
Key result
Temp.:
other: 25°C
Parameter:
other: cps
Value:
860
Conclusions:
The viscosity of Santicizer 278 was determined to be 860 cps at 25°C.
Executive summary:

The viscosity of Santicizer 278 was determined to be 860 cps at 25°C.

Description of key information

The viscosity of Santicizer Platinum P1700 was determined to be 750 cps at 25°C.

Read across data from the source dossier that tested structural analogue Santicizer S278 (benzyl 3-(isobutyryloxy)-1-isopropyl-2,2-dimethylpropyl phthalate) based on analogue is also available. A discussion and report on the read across strategy is provided as an attachment in Section 13 of the dossier.

The viscosity of Santicizer 278 was determined to be 860 cps at 25°C.

Key value for chemical safety assessment

Additional information