Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7100 (Viscosity)
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Deviations:
no
Qualifier:
according to guideline
Guideline:
CIPAC MT 192 (Viscosity of liquids by rotational viscometry)
Deviations:
no
GLP compliance:
yes
Type of method:
rotational viscometer (dynamic)
Specific details on test material used for the study:
Haloxyfop R Methyl Ester
Lot #: 20181014-110 (TSN403206)
Purity: 99.3% (R+S)
Key result
Temp.:
20°C
Parameter:
dynamic viscosity (in mPa s)
Value:
27 720
Key result
Temp.:
40°C
Parameter:
dynamic viscosity (in mPa s)
Value:
596.2
Key result
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
20 210
Key result
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
434.6
Conclusions:
Measured dynamic viscosity was 27720 mPa.s at 20ºC and 596.2 mPa.s at 40ºC
Kinematic viscosity was calculated as 20210 mm2/s at 20ºC and 434.6 mm2/s at 40ºC
Executive summary:

The purpose of this study was to evaluate the viscosity of the test substance.

The study was designed in accordance with accepted principles in order to meet the requirements of the Commission Regulation (EU) No 283/2013 in accordance with Regulation (EC) No 1107/2009 and US EPA OCSPP Series 830 - Product Properties Test Guidelines.

The viscosity of the test substance was measured at shear rates of 0.28 to 0.93 sec-1 at 20°C and 9.30 to 55.80 sec-1 at 40°C.

The test item was found to be Newtonian in its flow behaviour. Under the specified test conditions, the measured dynamic viscosity was 27720 mPa.s at 20°C and 596.2 mPa.s at 40°C. The kinematic viscosity was calculated as 20210 mm2/s at 20°C and 434.6 mm2/s at 40°C.

Description of key information

OECD 114

Key value for chemical safety assessment

Additional information