Registration Dossier

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2011-07-11
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: CIPAC method MT 22, 1944; reprinted 2007
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
capillary viscometer (static)
Specific details on test material used for the study:
No further details on the test substance available
Key result
Temp.:
20°C
Parameter:
other: cSt
Value:
194.3
Remarks on result:
other: The viscosity reported is the mean of 3 results.

Individual tests revealed: 194.8, 194.3 and 193.7 cSt.

Conclusions:
The kinematic viscosity of the substance was determined to be 194.3 cSt (mean of 3 results) at 20°C.

Description of key information

The kinematic viscosity of the test substance was determined in a GLP study according to CIPAC test method MT 22 to be 194.3 cSt at 20 °C, applying a capillary U-tube viscometer (Younis, 2011)

Key value for chemical safety assessment

Viscosity:
194.3 mm²/s (static)
at the temperature of:
20 °C

Additional information