Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
stability: thermal, sunlight, metals, other
Remarks:
Migrated from section 'Stability: thermal, sunlight, metals'
Type of information:
experimental study
Adequacy of study:
other information
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report date:
2013

Materials and methods

Test guideline
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Guideline 113 (Screening Test for Thermal Stability and Stability in Air)
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Details on test material:
Analytical purity: >= 98 % -<= 100 %
Lot/batch No.: 10353-11-064

Results and discussion

For thermal stability study

Test substance thermally stable:
no
Operating temperature
Operating temp.:
30 - 500 °C
Remarks on result:
other: exothemic reaction: 630J/g at 200°C.

Applicant's summary and conclusion