Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
01/2009
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: ASTM D6450-99
Version / remarks:
Standard Test method for Flash Point by Continuously Closed Cup (CCCFP) Tester
Deviations:
no
GLP compliance:
no
Type of method:
closed cup
Flash point:
164 °C
Atm. press.:
ca. 101 325 Pa

Atmospheric pressure not specified but not considered critical as the result is much above classification threshold.

Interpretation of results:
GHS criteria not met
Conclusions:
Not a flammable liquid.
Executive summary:

The purpose of the study was to measure the flash point of test item according to the method ASTM D6450 -99, closed cup.

The flash point of test item was measured as 164±0.2ºC.

Description of key information

Not a flammable liquid.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
164 °C

Additional information

The measurement was done according to ASTM D6450-99, not under GLP-conditions. The flash point is 164±0.2ºC.