EC number: 203-965-8 | CAS number: 112-38-9
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Adsorption / desorption
Administrative data
Link to relevant study record(s)
- Endpoint:
- adsorption / desorption: screening
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 2009-03-24 until 2009-08-21
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Reason / purpose for cross-reference:
- reference to same study
- Reason / purpose for cross-reference:
- reference to other study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 121 (Estimation of the Adsorption Coefficient (Koc) on Soil and on Sewage Sludge using High Performance Liquid Chromatography (HPLC))
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Remarks:
- The Analysis Department of the Groupement de Recherches de Lacq was recognised as compliant with the GLPs issued by the Groupement lnterministeriel des Produits Chimiques (GIPC) on 27 November 2007.
- Type of method:
- HPLC estimation method
- Media:
- soil/sewage sludge
- Specific details on test material used for the study:
- Details on properties of test surrogate or analogue material (migrated information):
No test surrogate or analogue material. - Radiolabelling:
- no
- Test temperature:
- 22 ± 0.5 °C
- Details on study design: HPLC method:
- EQUIPMENT
- Apparatus: A mass spectrometer fitted with a time of fly analyzer and a UV spectrometer were placed in series.
- Type: HP Autosampler, HP 1100 LC Pump, LCT Premier Mass Spectrometer, HP 1 100 UV Detector, Mettler Balance AG 245
- Type, material and dimension of analytical (guard) column:
Column:
Column: Agilent Zorbax CN Length 15 cm
Particle size (µm) 5
Internal diameter 2.1 mm
Injected volume (µL) 5.0
Flow rate of mobile phase (ml/min) 0.25
Wavelength analysis (nm) 210
- Detection system: mass spectrometer, UV
MOBILE PHASES
- Type: Methanol-water 55/45 v/v
- Experiments with additives carried out on separate columns: no
- pH: no data
- Solutes for dissolving test and reference substances:
A quantity of about 75 mg of 10-UNDENECENOIC ACID was accurately weighed (to the nearest 0.1 mg) and dissolved with 50 mL of methanol.
Preparation of the analytical reference items solufions
A quantity of about 48 mg of 1,1-bis(4-chlorophenyl)-2,2,2-tricfiloroethane was accurately weighed into a 50 mL volumetric flask. The volume was made with methanol.
A quantity of about 10 mg of phenanthrene was accurately weighed into a 50 mL volumetric flask. The volume was made with methanol.
A quantity of about 4 mg of naphtalene was accurately weighed into a 50 mL volumetric flask. The volume was made with methanol.
A quantity of about 34 mg of triadimenol was accurately weighed into a 50 mL volumetric flask. The volume was made with methanol.
A quantity of about 47 mg of methyl benzoate was accurately weighed into a 50 mL volumetric flask. The volume was made with methanol.
A quantity of about 30 mg of acetanilid was accurately weighed into a 50 mL volumetric flask. The volume was made with methanol.
A quantity of about 316mg of formamid was accurately weighed into a 50 m l volumetric flask. The volume was made with methanol.
DETERMINATION OF DEAD TIME
- Method: by inert substances which are not retained by the column
The dead time is measured by use of formamide, which is not retained on the column.
REFERENCE SUBSTANCES
- Identity: 1,1-bis(4-chlorophenyl)-2,2,2-tricfiloroethane, phenanthrene, naphtalene, triadimenol, methyl benzoate, acetanilid, formamid
DETERMINATION OF RETENTION TIMES
- Quantity of test substance introduced in the column: 7.5 µg
- Quantity of reference substances:
1,1-bis(4-chlorophenyl)-2,2,2-tricfiloroethane: 4.8 µg
phenanthrene: 1.0 µg
naphtalene: 0.4 µg
triadimenol: 3.4 µg
methyl benzoate: 4.7 µg
acetanilid: 3.0 µg
formamid: 31.6 µg
- Intervals of calibration: no data
REPETITIONS
- Number of determinations: 3
EVALUATION
- Calculation of capacity factors k': k' = (tr - to) / to
- Calculation of retention times: arithmetic mean of three test runs
- Determination of the log Koc value:
Regression equation: A correlation of log k' versus log K, is plotted for the appropriate reference substances. The regression equation is performed at regular intervals, so that account can be taken of possible changes in column performance. At least two determinations are performed and the value retained for log Kocof the test item is the mean of the two values obtained. - Computational methods:
- No data.
- Key result
- Type:
- Koc
- Value:
- 691.83
- Key result
- Type:
- log Koc
- Value:
- 2.84
- Details on results (HPLC method):
- - Retention times of reference substances used for calibration: in min
1,1-bis(4-chlorophenyl)-2,2,2-tricfiloroethane: 24.2
phenanthrene: 10.19
naphtalene: 5.41
triadimenol: 4.37
methyl benzoate: 3.4
acetanilid: 2.77
formamid: 2.09
- Details of fitted regression line (log k' vs. log Koc): log Koc = 2.868 log k' + 2.415 (r2 = 0.9839)
- Graph of regression line attached: no
- Average retention data for test substance:
Injection 1: 5.00 min
Injection 2: 4.99 min
Injection 3: 4.99 min - Transformation products:
- not measured
- Statistics:
- No statistics applied.
- Validity criteria fulfilled:
- yes
- Remarks:
- The temperature during the measurement did not vary by more than ± 1 °C. Repeatability and reproducibility validity criteria fulfilled.
- Conclusions:
- At the test conditions (HPLC), the adsorption coefficient of 10-UNDENECENOIC AClD was found to be log Koc = 2.84. Therefore test item can be considered as a less adsorptive substance.
- Executive summary:
The objective of this study was to determine the Adsorption Coefficient of the test item 10- UNDENECENOIC AClD applying the procedure described in the OECD Guideline 121 Adsorption Coefficient on Soil and on Sewage Sludge using High Performance Liquid Chromatography (HPLC). At the test conditions (HPLC), the adsorption coefficient of 10-UNDENECENOIC AClD was found to be log Koc = 2.84 (Koc = 691.83). This result is close to the log Koc 2.77 of reference substance acetanilide, which represents the lower end of adsorption values of the reference substances used. Therefore, the adsorption potential of the test item is considered low.
Reference
No remark.
Description of key information
Under the conditions of the available study (HPLC method – OECD Test Guideline 121), the adsorption coefficient was found to be log Koc = 2.84 (Koc 691.83). Therefore, the adsorption potential of the test item is considered low.
Key value for chemical safety assessment
- Koc at 20 °C:
- 692
Additional information
[LogKoc: 2.84]
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.