Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2009-12-07
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009
Report date:
2010

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))

Test material

Constituent 1
Reference substance name:
docosan-1-ol; hexacosan-1-ol; icosan-1-ol; octacosan-1-ol; tetracosan-1-ol
EC Number:
642-362-8
Cas Number:
1190630-03-5
Molecular formula:
not applicable: UVCB
IUPAC Name:
docosan-1-ol; hexacosan-1-ol; icosan-1-ol; octacosan-1-ol; tetracosan-1-ol
Details on test material:
Test Material: NAFOL 20+
Batch / Lot no.: 03600/MA

Results and discussion

Flammable gases (Lower and upper explosion limit)
Parameter:
upper explosion limit
Remarks on result:
other: The substance does not ignite within the 4 minutes test period, so the substance should not be considered as highly flammable.
Flammable solids
Test procedure:
burning time (test type not further specified)
Remarks:
or specified in description of method (migrated information)
Burning time:
> 300 s
Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.

Applicant's summary and conclusion

Executive summary:

Method

Equipment: gas burner

Measurement parameters

Substance form (long/wide/high) mm 250*20*10

Test period minutes: 4

gas burner flame: 5 mm

barometric pressure: 1008,6 mbar