Registration Dossier

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
27.09.2012-16.10.2012
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Justification for type of information:
Experimental test result performed using standard test guidelines
Qualifier:
according to guideline
Guideline:
other: as mention below
Principles of method if other than guideline:
Lowest temperature determined at which substance vaporizes to form an ignitable mixture in air
GLP compliance:
no
Specific details on test material used for the study:
- Name of test material : 1-(3-chlorophenyl)-4-(3-chloropropyl)piperazinium chloride
- Molecular formula : C13H19Cl3N2
- Molecular weight : 309.66 g/mol
- Smiles notation : ClCCCN1CCN{+}(.Cl{-})(c2cccc(Cl)c2)CC1
- InChl : 1S/C13H18Cl2N2.ClH/c14-5-2-6-16-7-9-17(10-8-16)13-4-1-3-12(15)11-13;/h1,3-4,11H,2,5-10H2;1H
- Substance type : Organic
- Physical state : Solid
Key result
Remarks on result:
other: The substance do not catch fire on being exposed to air at room temperature of 28 degC
Remarks:
at atm. press. of 975.0 hPa
Conclusions:
Test chemical did not catch fire on being exposed to air at room temperature of 28 deg C and atmospheric pressure of 975 hPa. This indicates that the substance, test chemical is not auto-flammable in nature.
Executive summary:

Test chemical did not catch fire on being exposed to air at room temperature of 28 deg C and atmospheric pressure of 975 hPa. This indicates that the substance, test chemical is not auto-flammable in nature.

Description of key information

Test chemical did not catch fire on being exposed to air at room temperature of 28 deg C and atmospheric pressure of 975 hPa. This indicates that the substance, test chemical is not auto-flammable in nature.

Key value for chemical safety assessment

Additional information

Test chemical did not catch fire on being exposed to air at room temperature of 28 deg C and atmospheric pressure of 975 hPa. This indicates that the substance, test chemical is not auto-flammable in nature.