Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 273-110-1 | CAS number: 68938-03-4 The complex combination of hydrocarbons produced by the distillation of products from the hydrogenation of isononanal. It consists predominantly of C6 olefins and paraffins and C9 alcohols and aldehydes and boiling in the range of approximately 110°C to 202°C (230°F to 396°F).
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Partition coefficient
Administrative data
Link to relevant study record(s)
- Endpoint:
- partition coefficient
- Type of information:
- experimental study
- Adequacy of study:
- weight of evidence
- Study period:
- 2008-10-09 to 2008-12-19
- Reliability:
- 3 (not reliable)
- Rationale for reliability incl. deficiencies:
- unsuitable test system
- Remarks:
- It is not clear from the study report, if the volatility of the substance was taken into consideration, therefore, the reliability of the measured data is questionable
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.8 (Partition Coefficient)
- Deviations:
- not specified
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
- Deviations:
- not specified
- GLP compliance:
- no
- Other quality assurance:
- ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
- Type of method:
- HPLC method
- Partition coefficient type:
- octanol-water
- Analytical method:
- high-performance liquid chromatography
- Key result
- Type:
- log Pow
- Partition coefficient:
- >= 5.4 - <= 6.2
- Temp.:
- 26 °C
- pH:
- 7.35
- Conclusions:
- Log Kow (Pow) for Oxooel LS9 is measured to be 5.4 to 6.2 at 26 degrees C.
- Executive summary:
As the test item is a mixture of several components, upper and lower limits of log Kow were determined using the HPLC method.
Log Kow (Pow) for Oxooel LS9 is measured to be 5.4 to 6.2 at 26 degrees C.
- Endpoint:
- partition coefficient
- Type of information:
- (Q)SAR
- Adequacy of study:
- weight of evidence
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- results derived from a valid (Q)SAR model and falling into its applicability domain, with adequate and reliable documentation / justification
- Justification for type of information:
- 1. SOFTWARE
EpiSuite v4.11, US EPA, 2012
2. MODEL (incl. version number)
KOWWIN v1.68
3. SMILES OR OTHER IDENTIFIERS USED AS INPUT FOR THE MODEL
see attachment (log Kow_QSAR justification.pdf)
4. SCIENTIFIC VALIDITY OF THE (Q)SAR MODEL
- Defined endpoint: n-octanol-water partition coefficient
- Unambiguous algorithm: KOWWIN uses a "fragment constant" methodology to predict log P, known as an Atom/Fragment Contribution (AFC) method. Coefficients for individual fragments and groups were derived by multiple regression of 2447 reliably measured log P values.
Results of the two successive multiple regressions (first for atom/fragments and second for
correction factors) yield the following general equation for estimating log P of any organic compound:
log P = Σ(fini ) + Σ(cjnj ) + 0.229
(num = 2447, r2 = 0.982, std dev = 0.217, mean error = 0.159)
where Σ(fini ) is the summation of fi (the coefficient for each atom/fragment) times ni (the number of
times the atom/fragment occurs in the structure) and b is the linear equation constant; Σ(cjnj ) is the summation of cj (the coefficient for each correction factor) times nj (the number
of times the correction factor occurs (or is applied) in the molecule).
- Defined domain of applicability:
Currently there is no universally accepted definition of model domain. However, users may wish to
consider the possibility that log P estimates are less accurate for compounds outside the MW
range of the training set compounds, and/or that have more instances of a given fragment than the
maximum for all training set compounds. It is also possible that a compound may have a functional
group(s) or other structural features not represented in the training set, and for which no fragment
coefficient was developed. These points should be taken into consideration when interpreting
model results.
Training Set Molecular Weights:
Minimum MW: 18.02
Maximum MW: 719.92
Average MW: 199.98
Validation Molecular Weights:
Minimum MW: 27.03
Maximum MW: 991.15
Average MW: 258.98
- Appropriate measures of goodness-of-fit and robustness and predictivity:
The model has been tested on an external validation dataset of 10,946 compounds.
Total Validation Set Statistics:
number in dataset = 10946
correlation coef (r2) = 0.943
standard deviation = 0.479
absolute deviation = 0.356
avg Molecular Weight = 258.98
Validation Set Estimation Error:
within <= 0.20 - 39.6%
within <= 0.40 - 66.0%
within <= 0.50 - 75.6%
within <= 0.60 - 82.5%
within <= 0.80 - 91.6%
within <= 1.00 - 95.6%
within <= 1.20 - 97.7%
within <= 1.50 - 99.1%
5. APPLICABILITY DOMAIN
- Descriptor domain: The components of the substance are within the molecular weight range of the training set compounds, and all fragments are represented in the training set. Thus, it is concluded, that the substance is within the applicability domain.
- Similarity with analogues in the training set: several linear and branched alkanes and alkenes, which are considered to be similar, are present in the training set.
6. ADEQUACY OF THE RESULT
The QSAR prediction is valid and of good reliability. Thus, the result is adequate for chemical safety assessment. - Principles of method if other than guideline:
- Estimation of the log Kow of the components by QSAR (EpiSuite v4.11, US EPA, 2012; KOWWIN v1.68)
- GLP compliance:
- no
- Remarks:
- not applicable for in silico study
- Type of method:
- calculation method (fragments)
- Partition coefficient type:
- octanol-water
- Key result
- Type:
- log Pow
- Partition coefficient:
- 4.17
- Temp.:
- 25 °C
- pH:
- >= 0 - <= 14
- Remarks on result:
- other: weighted mean
- Conclusions:
- The weighted mean log Kow of Oxooel LS9 was estimated to be 4.17 (EpiSuite v4.11, US EPA, 2012, KOWWIN v1.68).
Referenceopen allclose all
for details see attachment
Description of key information
The weighted mean log Kow of Oxooel LS9 was estimated to be 4.17 (EpiSuite v4.11, US EPA, 2012, KOWWIN v1.68).
Key value for chemical safety assessment
- Log Kow (Log Pow):
- 4.17
- at the temperature of:
- 25 °C
Additional information
As the test item is a mixture of several components, upper and lower limits of log Kow were determined using the HPLC method. Log Kow (Pow) for Oxooel LS9 was measured to be 5.4 to 6.2 at 26 degrees C.
However, it is not clear from the study report, if the volatility of the substance was taken into consideration, therefore, the reliability of the measured data is questionable. The contribution to the overall log Kow of the less volatile constituents, which are also more lipophilic, is probably overestimated in this experimental setting. In addition, no compound specific analytics were performed.
Thus, a calculation of the weighted mean log Kow based on QSAR (EpiSuite v4.11, US EPA, 2012, KOWWIN v1.68) was performed, which is used as key value for chemical safety assessment: The weighted mean log Kow of Oxooel LS9 was estimated to be 4.17.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.