Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
from 1998-01-07 to 1998-04-28
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
The study is regarded as reliable without restrictions because it was conducted in compliance with GLP regulation and guideline.
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
cited as: Directive 92/69/EEC, A9
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Version / remarks:
2004. Remark: (1983)
Deviations:
no
GLP compliance:
yes
Type of method:
closed cup
Flash point apparatus:
Setaflash apparatus
Key result
Flash point:
76.1 °C
Atm. press.:
1 013 hPa

The first definitive test was performed using a starting temperature of 70 °C and measurements were made at 1 °C intervals, a flash was observed at 76 °C. The second definitive test was performed using a starting temperature of 73 °C and measurements were made at 1 °C intervals, a flash was observed at 78 °C. The atmospheric pressure was 100.878 kPa during the testing period. The corrected lowest temperature where a flash was observed was 76.1 °C.

Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of Incozol LV was determined by a closed cup equilibrium method, the corrected lowest temperature where a flash was observed was 76.1 °C.
Executive summary:

A study was conducted according to Directive 92/69/EEC method A9 and ISO 3679-1983 to determine the flash point of Incozol LV using the closed cup equilibrium method. Therefore, the test item was added to the measurement cup of a Setaflash model. The first definitive test was performed using a starting temperature of 70 °C and measurements were made at 1 °C intervals, a flash was observed at 76 °C. The second definitive test was performed using a starting temperature of 73 °C and measurements were made at 1 °C intervals, a flash was observed at 78 °C. The atmospheric pressure was 100.878 kPa during the testing period. The corrected lowest temperature where a flash was observed was 76.1 °C.

Description of key information

The flash point of Incozol LV was determined by a closed cup equilibrium method, the corrected lowest temperature where a flash was observed was 76.1 °C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
76.1 °C

Additional information

A study was conducted according to Directive 92/69/EEC method A9 and ISO 3679-1983 to determine the flash point of Incozol LV using the closed cup equilibrium method. Therefore, the test item was added to the measurement cup of a Setaflash model. The first definitive test was performed using a starting temperature of 70 °C and measurements were made at 1 °C intervals, a flash was observed at 76 °C. The second definitive test was performed using a starting temperature of 73 °C and measurements were made at 1 °C intervals, a flash was observed at 78 °C. The atmospheric pressure was 100.878 kPa during the testing period. The corrected lowest temperature where a flash was observed was 76.1 °C.