Registration Dossier

Diss Factsheets

Physical & Chemical properties

Stability in organic solvents and identity of relevant degradation products

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
stability in organic solvents and identity of relevant degradation products
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2011
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions
Principles of method if other than guideline:
No guideline
GLP compliance:
no
Test substance stable:
no
Transformation products:
not measured

- Not soluble in acetone and acetonitrile


- Very low soluble and not stable in ethanol and methanol


- Low soluble and not stable in 1,4-dioxane, dimethylformamide (DMF), dimethylsulfoxide (DMSO) and N-pyrrolidone (NMP)

Conclusions:
- Not soluble in acetone and acetonitrile
- Very low soluble and not stable in ethanol and methanol
- Low soluble and not stable in 1,4-dioxane, dimethylformamide (DMF), dimethylsulfoxide (DMSO) and N-pyrrolidone (NMP)

Description of key information

- Not soluble in acetone and acetonitrile


- Very low soluble and not stable in ethanol and methanol


- Low soluble and not stable in 1,4-dioxane, dimethylformamide (DMF), dimethylsulfoxide (DMSO) and N-pyrrolidone (NMP)

Additional information

Bulk form:


The determination was conducted by UV/Vis spectrometer.