Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 201-248-4 | CAS number: 80-08-0
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Eye irritation
Administrative data
- Endpoint:
- eye irritation: in vitro / ex vivo
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- Experimental start and completion date: 27 January 2015
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 014
- Report date:
- 2015
Materials and methods
Test guideline
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 437 (Bovine Corneal Opacity and Permeability Test Method for Identifying Ocular Corrosives and Severe Irritants)
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
Test material
- Reference substance name:
- Dapsone
- EC Number:
- 201-248-4
- EC Name:
- Dapsone
- Cas Number:
- 80-08-0
- Molecular formula:
- C12H12N2O2S
- IUPAC Name:
- 4,4'-sulfonyldianiline
- Test material form:
- not specified
Constituent 1
Test animals / tissue source
- Species:
- other: Eyes from adult cattle.
- Strain:
- not specified
- Details on test animals or tissues and environmental conditions:
- Eyes from adult cattle (typically 12 to 60 months old) were obtained from a local abattoir as a by-product from freshly slaughtered animals. The eyes were excised by an abattoir employee after slaughter, and were placed in Hanks’ Balanced Salt Solution (HBSS) supplemented with antibiotics (penicillin at 100 IU/mL and streptomycin at 100 µg/mL). They were transported to the test facility over ice packs on the same day of slaughter. The corneas were prepared immediately on arrival.
Test system
- Vehicle:
- other: 20% w/v solution in 0.9% w/v sodium chloride solution.
- Controls:
- no
- Amount / concentration applied:
- For the purpose of this study the test item was prepared as a 20% w/v solution in 0.9% w/v sodium chloride solution.
The test item was formulated within two hours of being applied to the test system. It is assumed that the formulation was stable for this duration.
No analysis was conducted to determine the homogeneity, concentration or stability of the test item formulation. This is an exception with regard to GLP compliance statement. - Duration of treatment / exposure:
- The holders were gently tilted back and forth to ensure a uniform application of the item over the entire cornea. Each holder was incubated, anterior chamber uppermost, at 32 ± 1 ºC for 240 minutes.
- Observation period (in vivo):
- Not applicable
- Number of animals or in vitro replicates:
- Not applicable
- Details on study design:
- Study Design
Preparation of Corneas
All eyes were macroscopically examined before and after dissection. Only corneas free of damage were used.
The cornea from each selected eye was removed leaving a 2 to 3 mm rim of sclera to facilitate handling. The iris and lens were peeled away from the cornea. The isolated corneas were immersed (epithelial side uppermost) in a dish containing HBSS until they were mounted in Bovine Corneal Opacity and Permeability (BCOP) holders.
The anterior and posterior chambers of each BCOP holder were filled with complete Eagle’s minimum essential medium (MEM) and plugged. The holders were incubated at 32 ± 1 ºC for 60 minutes. At the end of the incubation period each cornea was examined for defects. Only corneas free of damage were used.
Selection of Corneas and Opacity Reading
The medium from both chambers of each holder was replaced with fresh complete MEM.
A pre treatment opacity reading was taken for each cornea using a calibrated opacitometer. The average opacity for all corneas was calculated.
Three corneas with opacity values close to the median value of all corneas were allocated to the negative control. Three corneas were also allocated to the test item and three corneas to the positive control item.
Treatment of corneas:
The MEM was removed from the anterior chamber of the BCOP holder and 0.75 ml of the test item preparation or control items were applied to the appropriate corneas.
The holders were gently tilted back and forth to ensure a uniform application of the item over the entire cornea. Each holder was incubated, anterior chamber uppermost, at 32 ± 1 ºC for 240 minutes.
At the end of the exposure period the test item preparation and control items were removed from the anterior chamber and the corne was rinsed three times with fresh complete MEM containing phenol red before a final rinse with complete MEM. The anterior and posterior chambers were refilled with fresh complete MEM. A post treatment opacity reading was taken and each cornea was visually observed.
Preparation of negative and positive control items.
The negative control item, 0.9 % w/v sodium chloride solution, was used as supplied.
The positive control item, Imidazole, was used as a 20% w/v solution in 0.9% w/v sodium chloride solution.
Results and discussion
In vitro
Results
- Irritation parameter:
- cornea opacity score
- Value:
- 0.6
- Remarks on result:
- no indication of irritation
Any other information on results incl. tables
In Vitro Irritancy Score
TheIn Vitro irritancy scores are summarized as follows:
Treatment |
In Vitro Irritancy Score |
Test Item |
0.6 |
Negative Control |
1.1 |
Positive Control |
96.9 |
Criteria for an Acceptable Test
The positive control In VitroIrritancy Score was within the range of 65.9 – 140.8. The positive control acceptance criterion was therefore satisfied.
The negative control gave opacity of ≤4.7 and permeability≤0.080. The negative control acceptance criteria were therefore satisfied.
Table1 Individual and Mean Corneal Opacity and Permeability Measurements
Treatment |
Cornea Number |
Opacity |
Permeability (OD) |
In VitroIrritancy Score |
||||
Pre-Treatment |
Post-Treatment |
Post-Treatment-Pre‑Treatment |
Corrected Value |
|
Corrected Value |
|||
Negative Control |
16 |
2 |
1 |
0 |
|
0.064 |
|
|
18 |
2 |
2 |
0 |
|
0.067 |
|
|
|
19 |
2 |
2 |
0 |
|
0.080 |
|
|
|
|
|
|
0.0* |
|
0.07 - |
|
1.1 |
|
Positive Control |
1 |
1 |
70 |
67 |
67.0 |
1.759 |
1.689 |
|
3 |
1 |
74 |
72 |
72.0 |
2.199 |
2.129 |
|
|
20 |
2 |
71 |
64 |
64.0 |
2.100 |
2.030 |
|
|
|
|
|
|
67.7· |
|
1.949· |
96.9 |
|
Test Item |
22 |
1 |
2 |
1 |
1.0 |
0.101 |
0.031 |
|
23 |
3 |
2 |
-1 |
0.0 |
0.066 |
0.000 |
|
|
24 |
4 |
3 |
-1 |
0.0 |
0.099 |
0.029 |
|
|
|
|
|
|
0.3· |
|
0.020· |
0.6 |
OD= Optical density * = Mean of the post-treatment -pre‑treatment values ¨= Mean permeability ·= Mean corrected value
Table2 Corneal Epithelium Condition Post Treatment
Treatment |
Cornea Number |
Observation |
Post Treatment |
||
Negative Control |
16 |
clear |
18 |
clear |
|
19 |
clear |
|
Positive Control |
1 |
cloudy |
3 |
cloudy |
|
20 |
cloudy |
|
Test Item |
22 |
clear |
23 |
clear |
Applicant's summary and conclusion
- Interpretation of results:
- GHS criteria not met
- Conclusions:
- The test item is not classified, no category, not requiring classification to UN GHS or EU CLP.
- Executive summary:
Introduction
The purpose of this test was to identify test items that can induce serious eye damage and to identify test items not requiring classification for eye irritation or serious eye damage. The Bovine Corneal Opacity and Permeability (BCOP) test method is an organotypic model that provides short-term maintenance of normal physiological and bioitem function of the bovine corneain vitro. In this test method, damage by the test item is assessed by quantitative measurements of changes in corneal opacity and permeability.
The test method can correctly identify test items (both chemicals and mixtures) inducing serious eye damage as well as those not requiring classification for eye irritation or serious eye damage, as defined by the United Nations (UN) Globally Harmonized System of Classification and Labelling of Items (GHS), and it was therefore endorsed as scientifically valid for both purposes. Test items inducing serious eye damage are classified as UN GHS Category 1. Items not classified for eye irritation or serious eye damage are defined as those that do not meet the requirements for classification as UN GHS Category 1 or 2 (2A or 2B), i.e. they are referred to as UN GHS No Category.
Method
The test item was applied at a concentration of 20% w/v in 0.9% w/v sodium chloride solution for 240 minutes. Negative and positive control items were tested concurrently. The two endpoints, decreased light transmission through the cornea (opacity) and increased passage of sodium fluorescein dye through the cornea (permeability) were combined in an empirically derived formula to generate anIn VitroIrritancy Score (IVIS).
Interpretation
The test item is classified according to the prediction model below:
IVIS
CLASSIFICATION
≤ 3
No category. Not requiring classification to UN GHS or EU CLP
> 3; ≤55
No prediction of eye irritation can be made
> 55
Category 1. UN GHS or EU CLP Causes serious eye damage
Results
The In Vitro irritancy scores are summarized as follows:
Treatment
In Vitro Irritancy Score
Test Item
0.6
Negative Control
1.1
Positive Control
96.9
Conclusion
No category. Not requiring classification to UN GHS or EU CLP.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.

EU Privacy Disclaimer
This website uses cookies to ensure you get the best experience on our websites.