Registration Dossier

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: According to international guideline(s), GLP-compliant, performed in recognized contract research organization, no restrictions, fully adequate for assessment.
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
effusion method: by loss of weight or by trapping vaporisate
Key result
Temp.:
20 °C
Vapour pressure:
0.15 Pa
Temp.:
25 °C
Vapour pressure:
0.28 Pa

Description of key information

0.28 Pa at 25°C, 0.15 Pa at 20 °C (OECD 104, EU A.4)

Key value for chemical safety assessment

Vapour pressure:
0.28 Pa
at the temperature of:
25 °C

Additional information