Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Justification for type of information:
Experimental test result performed using standard test methods
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Version / remarks:
2002
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
105 °C
Atm. press.:
96 830 Pa

TEST DESCRIPTION AND RESULT

Method Details

Observations

Remarks if, any

Method

Closed cup method using Pensky Martin’s Flash Point Apparatus

 

 

Principle of Flash point test

The flash point of a flammable liquid is the lowest temperature at which there will be enough flammable vapor to ignite when an ignition source is applied.

 

Type of method

·    Closed cup

 

Flash point apparatus

·    Abel’s flash pt apparatus

·    Pensky – Martin’s flash point apparatus

Pensky – Martin’s flash point apparatus

Volume of chemical used

Gm/ml

10ml

Ignition source

Gas lighter/flame

Gas lighter

Atmospheric pressure

hPa

968.3hPa

Flash point (RESULT)

°C

105°C

Interpretation of results:
other: non flammable
Conclusions:
The flash point of test chemical was determined to be 105°C at 96830 Pa.
Executive summary:

The flash point of test chemical was determined. The study was performed following the closed cup method using Pensky Martin’s Flash Point Apparatus. The flash point of the test chemical was determined to be 105°C at 96830 Pa.Thus, on the basis of criteria mentioned in CLP regulation, the chemical has flash point > 60°C hence the substance was considered to be not flammable.

Description of key information

Based on the available data from study report,the flash point of test chemical was determined. The study was performed following the closed cup method using Pensky Martin’s Flash Point Apparatus. The flash point of the test chemical was determined to be 105°C at 96830 Pa. Thus, on the basis of criteria mentioned in CLP regulation, the chemical has flash point > 60°C hence the substance was considered to be not flammable.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
105 °C

Additional information

Based on the available data from study report,the flash point of test chemical was determined. The study was performed following the closed cup method using Pensky Martin’s Flash Point Apparatus. The flash point of the test chemical was determined to be 105°C at 96830 Pa.

In a supporting study from handbook and authoritative database, the flash point of the test chemical was determined to be 120°C.

Additional study from handbook indicates the flash point of test chemical as 111°C.

In an another study from handbook,the flash point of test chemical was determined to be >100°C.

Thus, on the basis of criteria mentioned in CLP regulation, the chemical has flash point > 60°C hence the substance was considered to be not flammable.