Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
oxidising liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From April 06, 2009 to April 20, 2009
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: see 'Remark'
Remarks:
The study was conducted according to Method A.21 (Oxidizing Properties (Liquids) of Commission Regulation (EC) No 440/2008 of 30 May 2008. The GLP compliance is claimed through compliance with UK Good Laboratory Practice standards [Schedule 1, Good Laboratory Practice Regulations 1999 (SI 1999/3106 as amended by SI 2004/0994)].
Justification for data waiving:
other:
Cross-referenceopen allclose all
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to other study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009
Report date:
2009

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.21 (Oxidising Properties (Liquids))
Deviations:
no
Principles of method if other than guideline:
Not applicable
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Reference substance name:
Phytic acid
IUPAC Name:
Phytic acid
Details on test material:
- Name of test material (as cited in study report): Synthetic Inositol phosphates
- Physical state: Amber coloured liquid
- Lot/batch No.: 95816206JH-012
- Storage condition of test material: Room temperature in the dark

Study design

Contact with:
other: Not applicable

Results and discussion

Test results (Oxidising liquids)
Sample tested:
other: not specified (migrated information) based on its chemical structure, the test material is predicted to have no oxidising properties
Parameter:
other: based on its chemical structure, the test material is predicted to have no oxidising properties
Result:
other: Not applicable
Test results (Oxidising solids)
Sample tested:
other: not specified (migrated information) based on its chemical structure, the test material is predicted to have no oxidising properties
Parameter:
other: based on its chemical structure, the test material is predicted to have no oxidising properties
Result:
other: Not applicable

Any other information on results incl. tables

Please refer to the attached document titled 'Structure of Phytic acid 95816206JH-012'

Applicant's summary and conclusion

Interpretation of results:
other: no oxidising properties
Remarks:
Migrated information based on the chemical structure
Conclusions:
Based on its chemical structure, the test material is predicted to have no oxidising properties.
Executive summary:

An evaluation was conducted to determine the oxidising properties of the test material according to EU Method A.21 (Oxidizing Properties (Liquids)).

Based on its chemical structure, the test material is predicted to have no oxidising properties.