Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 943-553-1 | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Administrative data
First-aid measures
General advice : Do not leave the victim unattended.
If inhaled : If unconscious place in recovery position and seek medical advice.
If symptoms persist, call a physician.
In case of skin contact : Take off contaminated clothing and shoes immediately.
If on skin, rinse well with water.
In case of eye contact: Remove contact lenses.
Protect unharmed eye.
If eye irritation persists, consult a specialist.
If swallowed : Keep respiratory tract clear.
Do not give milk or alcoholic beverages.
Never give anything by mouth to an unconscious person.
If symptoms persist, call a physician.
Fire-fighting measures
Extinguishing media
Suitable extinguishing media:
Dry chemical
Alcohol-resistant foam
Water spray
Carbon dioxide (CO2)
Unsuitable extinguishing media: no data available
Special hazards arising from the substance or mixture
Specific hazards during firefighting: Do not allow run-off from fire fighting to enter drains or water courses.
Advice for firefighters
Special protective equipment for firefighters: Wear self contained breathing apparatus for fire fighting if necessary.
Further information: Collect contaminated fire extinguishing water separately. This must not be discharged into drains. Fire residues and contaminated fire extinguishing water must be disposed of in accordance with local regulations.
Accidental release measures
Personal precautions, protective equipment and emergency procedures
Personal precautions: no data available
Environmental precautions
Environmental precautions: Prevent product from entering drains. If the product contaminates rivers and lakes or drains inform respective authorities.
Methods and materials for containment and cleaning up
Methods for cleaning up : Wipe up with absorbent material (e.g. cloth, fleece).
Keep in suitable, closed containers for disposal.
Handling and storage
Precautions for safe handling
Advice on safe handling: For personal protection see section 8 of SDS.
Smoking, eating and drinking should be prohibited in the application area.
Advice on protection against fire and explosion: Normal measures for preventive fire protection.
Temperature class: no data available
Fire-fighting class: no data available
Dust explosion class: no data available
Conditions for safe storage, including any incompatibilities
Requirements for storage areas and containers: Containers which are opened must be carefully resealed and kept upright to prevent leakage. Electrical installations / working materials must comply with the technological safety standards.
Further information on storage conditions: no data available.
Advice on common storage : No materials to be especially mentioned.
German storage class: no data available
Other data: No decomposition if stored and applied as directed.
Transport information
Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all
Marine transport (UN RTDG/IMDG)
Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all
Exposure controls / personal protection
Control parameters
Contains no substances with occupational exposure limit values.
Exposure controls
Personal protective equipment
Respiratory protection : No personal respiratory protective equipment normally required.
Eye protection: Safety glasses
Skin and body protection: Protective suit
Hygiene measures: General industrial hygiene practice.
Environmental exposure controls
General advice: Prevent product from entering drains.
If the product contaminates rivers and lakes or drains inform
respective authorities.
Stability and reactivity
Reactivity: none
Chemical stability
The product is chemically stable.
Possibility of hazardous reactions
Hazardous reactions: Stable under recommended storage conditions., No hazards to be specially mentioned.
Conditions to avoid
Conditions to avoid: no data available
Incompatible materials
Materials to avoid : no data available
Hazardous decomposition products
Hazardous decomposition products: no data available
Thermal decomposition: no data available
Disposal considerations
Waste treatment methods
Product : The product should not be allowed to enter drains, water courses or the soil.
Dispose of in accordance with local regulations.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.