Registration Dossier

Diss Factsheets

Physical & Chemical properties

Explosiveness

Currently viewing:

Administrative data

Endpoint:
explosive properties of explosives
Type of information:
experimental study
Adequacy of study:
supporting study
Reliability:
4 (not assignable)
Rationale for reliability incl. deficiencies:
other: The test is performed according to EC guideline with some small deviations. However, there is no information on purity of the substance.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2007

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
Deviations:
yes
Remarks:
1)The weight of the falling hammer is 5 kg and dropped from 0.8 m, however, the energy applied is the same as guideline, 40 J or 40 Nm. 2) In contrast to the EC guideline aluminium foil is used to pack the substance. 3) Ten tests are performed.
GLP compliance:
not specified

Test material

Constituent 1
Chemical structure
Reference substance name:
METHYL (1R,2R,4S)-2-[HEX-5-EN-1-YL(METHYL)CARBAMOYL]-4-({7-METHOXY-8-METHYL-2-[4-(PROPAN-2-YL)-1,3-THIAZOL-2-YL]QUINOLIN-4-YL}OXY)CYCLOPENTANECARBOXYLATE
EC Number:
922-147-8
Cas Number:
1042695-87-3
Molecular formula:
C32H41N3O5S
IUPAC Name:
METHYL (1R,2R,4S)-2-[HEX-5-EN-1-YL(METHYL)CARBAMOYL]-4-({7-METHOXY-8-METHYL-2-[4-(PROPAN-2-YL)-1,3-THIAZOL-2-YL]QUINOLIN-4-YL}OXY)CYCLOPENTANECARBOXYLATE
Test material form:
solid: particulate/powder
Details on test material:
- Name of test material (as cited in study reports): JNJ-39125593-AAA (T003019)
- Physical state: solid
- Appearance: white powder
Specific details on test material used for the study:
no data

Results and discussion

Small-scale preliminary tests
Parameter:
other: More sensitive to shock than m-dinitrobenzene
Remarks on result:
negative (not further specified)
Remarks:
If all tests according to Lütolf method are negative, powder can be considered not shock sensitive as reference substance meta-dinitrobenzene is not shock sensitive in similar conditions (although not tested simultaneously in this study)

Any other information on results incl. tables

10 times negative. Not shock sensitive (sensitivity > 39.2 Nm).

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The test substance is not shock sensitive.