Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
no
Other quality assurance:
other: ISO 9001-2008
Remarks:
TECNIO Network
Specific details on test material used for the study:
Previously to perform flammability test, the sample was homogeneized using a mill to obtain a solid sample in powder form.
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period
Interpretation of results:
not classified based on GHS criteria
Conclusions:
The substance is not flammable.The result obtained in the preliminary screening test was the following: the substance did not ignite nor propagate combustion neither by burning with flame, nor showing smoldering of the powder within the four minutes test period.

Description of key information

Test according to EU Method A.10

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification

The result obtained in the preliminary screening test showed that the substance did not ignite nor propagate combustion neither by burning with flame, nor showing smoldering of the powder within the four minutes test period. According to the classification criteria in CLP Regulation, this substance has not to be classified as flammable solid.