Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

Key result for CAS# 297730-93-9:
Flash point: no flash point was exhibited using a Pensky-Martens closed cup flash point apparatus under the conditions of the test.

Key value for chemical safety assessment

Additional information

Discussion for CAS# 297730-93-9: