Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
No specific testing date available.
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
no
Type of method:
static method
Key result
Temp.:
20 °C
Vapour pressure:
70.93 hPa
Remarks on result:
other: 70.93 mbar +/- 0.54 mbar.
Key result
Temp.:
25 °C
Vapour pressure:
93.18 hPa
Remarks on result:
other: 93.18 mbar +/- 0.54 mbar.

The results presented in the following Figure 1 were obtained from the raw data reported in Table 1. The measured data is self-consistent, as shown by the coefficient of determination: R²=0.9998.

Definition of terms: Texp = Experimental temperature (°C)

Pexp = Experimental pressure (mbar)

Table 1: Data recorded during the experiment

Texp

Pexp

1/Texp

ln(Pexp)

[°C]

[mbar]

[K-1]

withPexpinmbar

5.55

29.38

0.00359

3.380

5.60

29.47

0.00359

3.383

5.61

29.55

0.00359

3.386

10.45

40.05

0.00353

3.690

10.43

39.98

0.00353

3.688

10.41

40.03

0.00353

3.690

20.29

71.95

0.00341

4.307

20.26

71.98

0.00341

4.307

20.29

71.89

0.00341

4.306

30.01

122.04

0.00330

4.822

30.00

121.88

0.00330

4.821

30.00

121.95

0.00330

4.822

39.69

196.51

0.00320

5.281

39.71

196.51

0.00320

5.281

39.74

196.45

0.00320

5.280

49.15

302.540

0.00310

5.704

49.16

302.604

0.00310

5.704

49.13

302.584

0.00310

5.704

The uncertainty of measurement for pressure was about 0.4 mbar and for temperature, it was about 0.05 °C

The measured vapour pressures were used to regress the coefficients of Antoine's law reported in Table 2 using the following equation. They enable to calculate the vapour pressure of the test item at any given temperature provided this temperature falls within the range specified in the same table. Ln P = A + (B/(T + C))

With Pcal (calculated pressure) in mbar and T in K

Table 2: Antoine's law coefficients

A

B

C

18.04779

-3413.43701

-45.55132

The maximum error involved by the modelling of vapour pressure with our Antoine’s law is about 0.8 mbar which is in magnitude of the uncertainty of measurement of pressure.

Table 3: Average of measured values and calculated data with Antoine’s law coefficients

Texp

Pexp

Pcalc

Pexp-Pcalc

[°C]

[mbar]

[mbar]

[mbar]

5.59

29.47

30.25

0.78

10.43

40.02

40.75

0.72

20.28

71.94

72.04

0.10

30.00

121.95

121.15

0.80

39.72

196.49

196.06

0.43

49.15

302.58

302.97

0.40

Conclusions:
The vapour pressure of the test item at 20 °C is 70.93 mbar +/- 0.54 mbar.
The vapour pressure of the test item at 25 °C is 93.18 mbar +/- 0.54 mbar.
Executive summary:

In a study (2016), the vapour pressure of trifluoromethanesulfonic anhydride was determined using a static cell, according to the OECD 104 and EU A.4 guidelines. Measurements were performed at temperatures from 5 °C up to 49 °C. For each temperature, once the temperature and pressure inside the cell were stable, three readings were made, spaced by not less than 5 minutes. Using the Antoine’s law, the vapour pressure was calculated at 20 and 25°C as follows :

The vapour pressure at 20°C was 70.93 mbar +/- 0.54 mbar.

The vapour pressure at 25°C was 93.18 mbar +/- 0.54 mbar.

Description of key information

One reliable key study scored as reliability 1 is available for this endpoint. The vapour pressure of trifluoromethanesulfonic anhydride was determined using a static cell, according to the OECD 104 and EU A.4 guidelines. The vapour pressure at 20°C was 70.93 mbar +/- 0.54 mbar. The vapour pressure at 25°C was 93.18 mbar +/- 0.54 mbar.

Key value for chemical safety assessment

Vapour pressure:
70.93 hPa
at the temperature of:
20 °C

Additional information