Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Endpoint:
auto-flammability
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Not stated in report
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP/Guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2001
Report date:
2001

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
Deviations:
not specified
GLP compliance:
yes

Test material

Constituent 1
Test material form:
other: solid
Details on test material:
Purified active substance. Lot# AAP 12536, with purity = 99.7%.

Results and discussion

Auto-ignition temperature (liquids / gases)
Auto-ignition temperature:
396 °C
Atm. press.:
1 012 mBar
Remarks on result:
other:

Any other information on results incl. tables

The autoignition temperature of Kordek 573T industrial microbiocide is 396C at 1012 mbar.

Applicant's summary and conclusion

Conclusions:
The autoignition temperature of Kordek 573T industrial microbiocide is 396C at 1012 mbar.
Executive summary:

The autoignition temperature of Kordek 573T industrial microbiocide was determined and is 396C at 1012 mbar.