Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2010
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Acceptable, well-documented study report which meets basic scientific principles. No GLP lab.
Justification for type of information:
A discussion and report on the read across strategy is given as an attachment in IUCLID Section 13.
Reason / purpose for cross-reference:
read-across: supporting information
Qualifier:
according to guideline
Guideline:
ISO No., other: ASTM D 93
GLP compliance:
no
Remarks:
No GLP certified lab
Type of method:
closed cup
Key result
Flash point:
63 °C
Atm. press.:
1 atm
Conclusions:
The measured flash point at 1 atm is 63°C according to the ASTM D 93 methodology.
Executive summary:

The measured flash point at 1 atm is 63°C according to the ASTM D 93 methodology.

Description of key information

The flash point in closed cup is above 61°C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
63 °C

Additional information

The flash point in closed cup is above 61°C.