Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 211-779-3 | CAS number: 695-12-5
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Biodegradation in water: screening tests
Administrative data
Link to relevant study record(s)
- Endpoint:
- biodegradation in water: ready biodegradability
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 2017-06-22 to 2017-10-11
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 301 F (Ready Biodegradability: Manometric Respirometry Test)
- Version / remarks:
- July 1992
- GLP compliance:
- yes (incl. QA statement)
- Specific details on test material used for the study:
- Test item: Vinylcyclohexane
Chemical name:: Ethenylcyclohexane
Molecular formula: C8H14
CAS number: 695-12-5
Lot number: VCH/7/17K1
Purity: 99.8 %
ThOD: 3.34 mg O2/mg test substance (calculated by Hydrotox on the basis of the molecular formula)
Water solubility: Insoluble - Oxygen conditions:
- aerobic
- Inoculum or test system:
- activated sludge, domestic, non-adapted
- Details on inoculum:
- - Source of inoculum/activated sludge (e.g. location, sampling depth, contamination history, procedure): Activated sludge, municipal wastewater treatment plant Breisgauer Bucht, 30 mg dry solids per litre. The treatment plant clarifies predominantly domestic wastewater and has a capacity of 600.000 inhabitant equivalents. Sampling date of activated sludge was on 26 June 2017. The dry solid content of the activated sludge was 3.5 g/L. It was determined by weight measurements after drying at 105°C for 4 hours (mean of triplicate measurements). The activated sludge was washed twice with tap water by settling the sludge, decanting the supernatant and re-suspending the sludge.
- Duration of test (contact time):
- 28 d
- Initial conc.:
- 100 mg/L
- Based on:
- ThOD
- Initial conc.:
- 3.34 other: mg O2/mg test substance
- Based on:
- ThOD
- Parameter followed for biodegradation estimation:
- O2 consumption
- Details on study design:
- - Method: The Manometric Respirometry Test determines the ready biodegradability of test items following their oxygen consumption in closed flasks at a constant temperature (±1°C) in a range of 20 – 24°C. The consumption of oxygen is determined by measuring the negative pressure in the flasks after absorption of the evolved carbon dioxide in sodium hydroxide. A solution or suspension of the test item in a mineral medium, corresponding to 100 mg/L test item giving at least 50 – 100 mg/L of theoretical oxygen demand (ThOD), is inoculated with activated sludge (30 mg d.s./L) for 28 days. The amount of oxygen taken up by the microbial population during the biodegradation of the test item (corrected for uptake by blank inoculum, run in parallel) is expressed as a percentage of the ThOD or the chemical oxygen demand (COD). The pass level for ready biodegradability is 60% of ThOD and must be reached within a 10-d window. The 10-d window begins when the degree of biodegradation reaches 10%.
TEST CONDITIONS
- Composition of medium:
Mineral medium
A: Potassium dihydrogenphosphate KH2PO4 = 8.50 g
Dipotassium hydrogenphosphate K2HPO4 = 21.75 g
Disodium hydrogenphosphate dihydrate Na2HPO4 * 2 H2O = 33.40 g
Ammonium chloride NH4Cl = 0.50 g
are dissolved in demineralised water and made up to 1 litre.
B: Calcium chloride dihydrate CaCl2 * 2H2O = 36.4 g
is dissolved in demineralised water and made up to 1 litre.
C: Magnesium sulfate heptahydrate MgSO4 * 7H2O = 22.5 g
is dissolved in demineralised water and made up to 1 litre.
D: Iron (III) chloride hexahydrate FeCl3 * 6H2O = 0.25 g
is dissolved in demineralised water, stabilised with one drop of concentrated HCl and made up to 1 litre.
For preparation of the mineral medium 10 mL of solution (A) is mixed with 900 mL demineralised water, 1 mL each of solutions (B), (C) and (D) are added and the volume is made up to 1 litre. Before use, the mineral medium was aerated for about half an hour, the pH was 7.6.
- Test temperature: 20 – 24°C
- pH: 7.6
- pH adjusted: no
- Continuous darkness: yes/no
Test item
The test item was added directly. Therefore 164 mL mineral medium were filled into the test vessels and the test item was pipetted directly into the bottles. 6.1 µL of the test item were added, corresponding to a concentration of 100.1 mg ThOD/L (the density of the test item of 0.806 g/cm3 was considered). The initial pH was 7.6 and was not adjusted.
Reference substance
A stock solution of 128.2 mg/L sodium acetate in mineral medium was prepared. 164 mL of this stock solution were added into the reference vessels corresponding to a concentration of 100.0 mg ThOD/L. The initial pH was 7.6 and was not adjusted.
Toxicity control
164 mL of the stock solution with 128.2 mg/L sodium acetate (s. 5.5) and 6.1 µL of the test item were added into the toxicity control vessel, corresponding to a concentration of 200.1 mg ThOD/L. The initial pH was 7.6 and was not adjusted.
Abiotic control
6.1 µL of the test item and 2.46 g sodium azide were added into the abiotic control vessel which had been filled with 164 mL mineral medium previously. This corresponds to a test item concentration of 100.1 mg ThOD/L and sodium azide concentration of 15 g/L. The initial pH was 7.5 and was not adjusted. No inoculum was added.
Blank
164 mL of the pre-aerated mineral medium with a pH of 7.6 were filled into the blank vessels. The initial pH was 7.6 and was not adjusted.
Inoculum
Activated sludge from the municipal wastewater treatment plant Breisgauer Bucht was used as inoculum with a concentration corresponding to 30 mg dry solids per litre. The treatment plant clarifies predominantly domestic wastewater and has a capacity of 600.000 inhabitant equivalents. Sampling date of activated sludge was on 26 June 2017. The dry solid content of the activated sludge was 3.5 g/L. It was determined by weight measurements after drying at 105°C for 4 hours (mean of triplicate measurements). The activated sludge was washed twice with tap water by settling the sludge, decanting the supernatant and re-suspending the sludge.
TEST SYSTEM
- Culturing apparatus and measurement equippment: OxiTop®-Control from WTW, Weilheim and the Sensomat-System from Aqualytic GmbH & Co., Langen were used as test systems. They consist of narrow-necked glass bottles with rubber sleeve inserts for NaOH pellets, in which the carbon dioxide evolved is absorbed. The liquid volume was fixed as 164 mL each. Magnetic stir bars were introduced into the bottles which were positioned on a stirrer platform. The bottles were sealed tightly with the measuring heads with a measuring range of 500 – 1350 hPa. Every 112 minutes the current pressure was measured and stored by each measuring head. At the end of the experiment pressure data were read out via an infrared interface to the controller unit and afterwards data were transferred via a RS232 interface using the Achat OC software of WTW to an Excel file where further data processing was carried out. Additionally, several measured values were randomly read out and recorded by hand and were afterwards compared with the printed excel table for quality control.
- Number of culture flasks/concentration: In total three reactors containing the test item, three reactors containing only inoculum (blank), three reactors containing the reference compound (reference), one reactor containing reference compound and test item (toxicity control) and one reactor containing the test item and the biozid sodium azide (abiotic control) were set up. The test flasks were filled as described in paragraphs 5.4 - 5.8 and tempered to the incubation temperature for about 2 hours. Afterwards, 1.4 mL of the inoculum were added into each flask except the abiotic control vessel, one sodium hydroxide pellet was added to each rubber quiver inserted in the flasks and the flasks were sealed tightly with the measuring heads and the test was started. After 28 days the data were read out and the pH in the flasks was measured on the next day. - Reference substance:
- other: sodium acetate
- Key result
- Parameter:
- % degradation (O2 consumption)
- Value:
- 7.5
- Sampling time:
- 28 d
- Details on results:
- The biodegradation at the end of the test (day 28) was 7.5% of ThOD (mean of three replicates).
- Results with reference substance:
- The reference compound sodium acetate reached the pass level for ready biodegradability (60% ThOD within a 10-day window) within 8 days.
- Validity criteria fulfilled:
- yes
- Interpretation of results:
- not readily biodegradable
- Conclusions:
- The test item is not readily biodegradable.
- Executive summary:
The biodegradation of vinylcyclohexane was studied in the Manometric Respirometry Test according to the OECD test guideline 301 F with activated sludge from a domestic sewage treatment plant (The dry solid content of the activated sludge was 3.5 g/L). Vinylcyclohexane was applied with 100.1 mg ThOD/L (the density of the test item of 0.806 g/cm3 was considered). The experiment was conducted in compliance with the OECD GLP standards.
The pressure decrease in the reaction vessels was measured over the complete experimental phase of 28 days. The amount of O2 consumed by the activated sludge was calculated from the decrease of pressure in the reaction vessel.
The biodegradation at the end of the test (day 28) was 7.5 % of ThOD (mean of three replicates), thus the test item did not reach the criteria for ready biodegradability (60 % ThOD within a 10-d window). The degradation of the toxicity control after 14 days was > 25 %. Thus, the test item had no inhibitory effect on the inoculum. No abiotic degradation could be detected.
Vinylcyclohexane is considered to be not readily biodegradable.
Reference
Test item
The biodegradation at the end of the test (day 28) was 7.5 % of ThOD (mean of three replicates). Therefore, the test item didn’t reach the criteria for ready biodegradability (60 % of ThOD within a 10-d window). The pH in the test vessels at the end of the test was 7.5.
Toxicity control
The degradation in the toxicity control reached 36.5 % within 8 days and was thus above the criterion for inhibition effects to the inoculum (< 25 % on day 14). The test item had no toxic effect to the inoculum according to the validity criteria of OECD 301. The pH in the toxicity control vessel at the end of the test was 9.0.
Abiotic control
No abiotic degradation could be detected in the abiotic control. Temporarily, an underflow of the admissible range occurred which means that instead of an oxygen consumption an overpressure was measured. In these cases, the degradation values were equated with 0. The pH in the abiotic control vessel at the end of the test was 8.5.
Reference item
The reference compound sodium acetate reached the pass level for ready biodegradability (60 % ThOD within a 10-day window) within 8 days. The pH in the reference vessels at the end of the test was between 9.0 and 9.1.
Blank
The oxygen consumption of the blanks was 18.8 mg/L in 28 days (mean of three replicates, see table 1). The pH in the blank vessels at the end of the test was 7.5.
Figure 1 below displays the degradation of the test item, reference item, toxicity control and abiotic control.
The temperature was 21.8 – 22.8 °C throughout the whole study.
Description of key information
In a GLP test according to OECD guideline 301 F, the biodegradation of vinylcyclohexane was 7.5 % of ThOD (mean of three replicates) after 28 days. Thus, the test item is not readily biodegradable.
Key value for chemical safety assessment
- Biodegradation in water:
- under test conditions no biodegradation observed
- Type of water:
- freshwater
Additional information
For further details on the assessment of the persistency of vinylcyclohexane please refer to the PBT assessment report in IUCLID section 13.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.