Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report date:
2016

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
effusion method: Knudsen cell

Test material

1
Reference substance name:
Esterification products of Grape seeds, Vitis vinifera L. (Vitaceae), extract with hexadecanoyl chloride
EC Number:
941-319-3
Molecular formula:
Unknown (Substance of Unknown or Variable Composition)
IUPAC Name:
Esterification products of Grape seeds, Vitis vinifera L. (Vitaceae), extract with hexadecanoyl chloride
Test material form:
solid: particulate/powder

Results and discussion

Vapour pressure
Key result
Temp.:
ca. 60 °C
Vapour pressure:
ca. 0.002 Pa

Applicant's summary and conclusion

Conclusions:
Refer to attached study report. The vapour derived from the study is 2.04E-03 Pa at 60°C.
Executive summary:

At all experiments no reproducible weight loss was observed. At 90 °C the test item was nearly completely bubbled over. Therefore it was not possible to determine the vapour pressure thusly. Also a calculation of the vapour pressure using EPIwin is not possible because the test item is 100 % UVCB. Only the highest value of the vapour pressure, derived from all measurements can be stated with 2.04*10-03 Pa at 60 °C with a standard deviation of 1.43*10-04 Pa. Therefore, the result of the test can be considered valid.