Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 458-680-3 | CAS number: 797751-44-1 WASOX-VMAC2
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Flammability
Administrative data
Link to relevant study record(s)
- Endpoint:
- substances / mixtures which in contact with water emit flammable gases
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- guideline study with acceptable restrictions
- Remarks:
- According to EU Method A. 12 with GLP.
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.12 (Flammability (Contact with Water))
- GLP compliance:
- yes
- Key result
- Remarks on result:
- not measured/tested
- Interpretation of results:
- other: Not classified (CLP Regulation EC no. 1272/2008)
- Conclusions:
- The Flammability in Contact with Water test was not performed experimentally because practical experience exists (e.g. when preparing test substance solutions for testing for fish toxicity or hydrolysis). The test substance in contact with water does not develop any gas at all. Therefore also no highly flammable gases in dangerous quantities at a minimum rate of 1 liter/kg per hour are evolved.
The test substance is therefore regarded as not being "flammable in contact with water". - Executive summary:
The Flammability in Contact with Water test was not performed experimentally because practical experience exists (e.g. when preparing test substance solutions for testing for fish toxicity or hydrolysis). The test substance in contact with water does not develop any gas at all. Therefore also no highly flammable gases in dangerous quantities at a minimum rate of 1 liter/kg per hour are evolved. The test substance is therefore regarded as not being "flammable in contact with water".
- Endpoint:
- pyrophoric liquids
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 2005-04-21
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- guideline study with acceptable restrictions
- Remarks:
- According to EU method A.13 with GLP.
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.13 (Pyrophoric Properties of Solids and Liquids)
- GLP compliance:
- yes
- Key result
- Remarks on result:
- not measured/tested
- Interpretation of results:
- other: Not classified (CLP Regulation EC no. 1272/2008)
- Conclusions:
- The test was not performed experimentally because practical experience, e.g. when handling small amounts of the test substance repeatedly in air during testing for various properties. Also experience from the test for auto-ignition of the test substance at elevated temperature is available. The test substance does not ignite in air at ca. 20 °C and even not at temperatures up to 300 °C. The test substance is therefore regarded as not being pyrophoric.
- Executive summary:
The test was not performed experimentally because practical experience, e.g. when handling small amounts of the test substance repeatedly in air during testing for various properties. Also experience from the test for auto-ignition of the test substance at elevated temperature is available. The test substance does not ignite in air at ca. 20 °C and even not at temperatures up to 300 °C. The test substance is therefore regarded as not being pyrophoric.
- Endpoint:
- flammable solids
- Data waiving:
- study technically not feasible
- Justification for data waiving:
- the study does not need to be conducted because the substance is a liquid
- Justification for type of information:
- JUSTIFICATION FOR DATA WAIVING
The study does not need to be conducted beacuse the substance is a liquid - Reason / purpose for cross-reference:
- data waiving: supporting information
Referenceopen allclose all
Description of key information
The flammability in contact with water test and also the test for pyrophoric properties were not performed experimentally. But the test substance is regarded, due to experience, neither as not being "flammable in contact with water" nor as not being pyrophoric.
Key value for chemical safety assessment
- Flammability:
- not classified
Additional information
The Flammability in Contact with Water test was not performed experimentally because practical experience exists (e.g. when preparing test substance solutions for testing for fish toxicity or hydrolysis). The test substance in contact with water does not develop any gas at all. Therefore also no highly flammable gases in dangerous quantities at a minimum rate of 1 liter/kg per hour are evolved. The test substance is therefore regarded as not being "flammable in contact with water".
The test for pyrophoric properties was not performed experimentally because practical experience, e.g. when handling small amounts of the test substance repeatedly in air during testing for various properties. Also experience from the test for auto-ignition of the test substance at elevated temperature is available. The test substance does not ignite in air at ca. 20 °C and even not at temperatures up to 300 °C. The test substance is therefore regarded as not being pyrophoric.
Justification for classification or non-classification
Based on the available data, the substance is not classified for flammability according to CLP Regulation (EC) no. 1272/2008.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.