Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
GLP compliance:
yes (incl. QA statement)
Type of method:
capillary viscometer (static)

Test material

1
Reference substance name:
Reaction product of tin, citric acid and nitric acid
EC Number:
944-119-4
Molecular formula:
not available
IUPAC Name:
Reaction product of tin, citric acid and nitric acid
Test material form:
liquid
Details on test material:
Charge: 170001CAKO

Results and discussion

Viscosityopen allclose all
Key result
Temp.:
20°C
Parameter:
dynamic viscosity (in mPa s)
Value:
1.65
Key result
Temp.:
40°C
Parameter:
dynamic viscosity (in mPa s)
Value:
1.14
Key result
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
1.35
Key result
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
0.94

Any other information on results incl. tables

Results in detail

Viscosity determination of the test item at 20 °C

 

Kinematic viscosity

[mm2/s]

Dynamic viscosity*)

[mPa*s]

1stdetermination

1.3527

1.6547

2nddetermination

1.3474

1.6482

Mean value

1.35

1.65

*) calculated with a density of the test item of ρ= 1.22328 g/ml

 

Viscosity determination of the test item at 40 °C

 

Kinematic viscosity

[mm2/s]

Dynamic viscosity*)

[mPa*s]

1stdetermination

0.9497

1.1461

2nddetermination

0.9378

1.1318

Mean value

0.94

1.14

*) calculated with a density of the test item of ρ= 1.20685 g/ml

The estimated accuracy is ± 1 %.

Applicant's summary and conclusion