Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Justification for type of information:
Performed by the manufacturer using water-free material.
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Specific details on test material used for the study:
a representative sample (#BP16120710) was stripped of as much water as possible to make batch referred to as PAH/225/134/5 to use for testing.
An FTIR was ran on sample #BP16120710 and PAH/225/134/5 to ensure that no degradation occurred during the removal of the solvent.
Key result
Flash point:
> 85 °C
Atm. press.:
ca. 1 atm

No flash observed up to the maximum reported temperature of 85 C

Interpretation of results:
GHS criteria not met
Conclusions:
Not classified as flammable based on these results.
Executive summary:

No flash observed up to the maximum reported temperature of 85 C

Description of key information

No flash observed up to the maximum reported temperature of 85 C

Key value for chemical safety assessment

Additional information