Administrative data

Link to relevant study record(s)

Reference
Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016-12-06
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Reason / purpose for cross-reference:
reference to same study
Qualifier:
according to guideline
Guideline:
OECD Guideline 103 (Boiling Point)
Version / remarks:
1995
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.2 (Boiling Temperature)
Version / remarks:
2008
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
signed 2013-03-22
Type of method:
differential scanning calorimetry
Key result
Atm. press.:
>= 1 019.8 - <= 1 020.2 hPa
Decomposition:
no
Remarks on result:
not determinable
Remarks:
No melting point in the temperature range 25 °C - 500 °C

In the temperature range of 390 °C – 450 °C, an endothermic effect could be detected. After the measurement the colour of the test item changed from yellow powder to grey sintered solid.

Results of the DSC-measurements

Sample weight / mg Start of Effect / °C Range of effect / °C Weight loss / mg Atmospheric pressure / hPa
16.64 390 390 – 450 (endo) --- 1019.8
15.76 390 390 – 450 (endo) --- 1020.2

The test item showed no distinct endothermic signal in the test that can be assigned with a boiling of the test item. The very small and broad endothermic effect is caused by another endothermic process (e.g. sintering, gas evolution). Therefore the test item has no boiling point in the temperature range 25 °C - 500 °C.

Conclusions:
The test item Potassium hexacyanocobaltate (III) has no boiling point from 25 °C up to a temperature of 500 °C at atmospheric pressure (1020 hPa) as determined by differential scanning calorimetry according to Regulation EC No. 440/2008 Method A.1. and A.2., OECD Test Guideline 102 and 103 (1995).

Description of key information

The test item Potassium hexacyanocobaltate (III) has no boiling point from 25 °C up to a temperature of 500 °C at atmospheric pressure (1020 hPa) as determined by differential scanning calorimetry according to Regulation EC No. 440/2008 Method A.1. and A.2., OECD Test Guideline 102 and 103 (1995).

Key value for chemical safety assessment

Additional information