Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 939-582-4 | CAS number: 1471315-26-0
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Skin irritation / corrosion
Administrative data
- Endpoint:
- skin irritation / corrosion
- Remarks:
- in vitro
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 5 June - 6 June 2012
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- other: GLP-Guideline study.
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 012
- Report date:
- 2012
Materials and methods
Test guidelineopen allclose all
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 431 (In Vitro Skin Corrosion: Human Skin Model Test)
- Version / remarks:
- adopted 13. April 2004
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EU Method B.40 (In Vitro Skin Corrosion: Transcutaneous Electrical Resistance Test (TER))
- Version / remarks:
- adopted 30. May, 2008
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Remarks:
- Bayerisches Landesamt für Gesundheit und Lebensmittelsicherheit, München, Germany
Test material
- Reference substance name:
- Fatty acids, C16-18 (even numbered), aluminum salts
- EC Number:
- 939-582-4
- Cas Number:
- 1471315-26-0
- Molecular formula:
- Not applicable (UVCB substance)
- IUPAC Name:
- Fatty acids, C16-18 (even numbered), aluminum salts
- Details on test material:
- - Name of test material (as cited in study report): Fatty acids, tallow, hydrogenated, aluminium salts
- Physical state: white solid powder
- Analytical purity: 84.33%
- Impurities (identity and concentrations): ash content 9.17%; humidity 0.75%; free fatty acids 14.13%; water-soluble salts 0.61%; aluminium 4.13%
- Purity test date: 2012-02-14
- Lot/batch No.: C200752-001
- Expiration date of the lot/batch: 2014-02-14
- Storage conditions: at room temperature
- Other: CAS 91770-05-7
Constituent 1
Test animals
- Species:
- human
- Strain:
- other: reconstructed human epidermis (EpiDerm)
- Details on test animals or test system and environmental conditions:
- TEST SKIN MODEL
- Source: MaTek (Epi-200)
- Adaptions to cell culture conditions: Upon receipt, the tissues were transferred into 6-well plates containing 900 µL prewarmed assay medium per well. The 6-well plates were incubated in a humidified incubator at 37 ± 1 °C, 5% CO2 for at least 1 h.
ENVIRONMENTAL CONDITIONS (Incubator)
- Temperature (°C): 37 ± 1
- CO2 gas concentration (%) 5
- Humidity: maximum
Test system
- Type of coverage:
- open
- Preparation of test site:
- other: intact reconstructed human epidermis
- Vehicle:
- unchanged (no vehicle)
- Controls:
- other: concurrent negative control tissue treated with aqua dest.
- Amount / concentration applied:
- TEST MATERIAL
- Amount applied: 25 mg were applied directly atop the tissue, to ensure good contact the test item was moistened with 25 µL H2O - Duration of treatment / exposure:
- 3 and 60 min exposure
- Observation period:
- Not applicable
- Number of animals:
- Not applicable. Tests were performed in duplicate for each dose group.
- Details on study design:
- REMOVAL OF TEST SUBSTANCE
- Washing: after the incubation period, the inserts were washed carefully with PBS about 20 times.
- Time after start of exposure: 3 or 60 min, respectively
CELL VIABILITY MEASUREMENTS
- Method: MTT assay
- Details on method used: for viability testing, the inserts were placed in a prepared 24-well plate containing 300 µL MTT medium and further incubated for 3 h (37 °C, 5% CO2). After the incubation period, the MTT solutions were replaced by PBS for 3 times (washing) and afterwards the tissues were dried and transferred into extraction plates and covered with isopropanol. Extraction was carried out for 2 hours at room temperature on a shaker. Plates were placed for 15 ± 2 min on a plate shaker. The inserts were pierced with an injection needle after the incubation period to allow the extracts to run through the tissues into the corresponding wells. The inserts were discarded and the extraction plates again shaked for 15 minutes. Measurement of cell viability was carried out in 96-well plates. Per tissue, triplicates of 200 µL aliqouts were pipetted into 96-wells and absorption was measured at 550 nm without reference wavelength in a plate spectrophotometer (TECAN Infinite 200, TECAN Austria).
PRE-EXPERIMENTS
- To check the non-specific MTT-reducing capability of the test item 30 mg of the test item were mixed with 1 mL MTT medium and incubated for 1 h at room temperature. If the mixture turns blue/purple, the test item is presumed to have reduced MTT. Furthermore, the colouring potential of the test item in water was tested (25 mg test item mixed with 300 µL water).
EVALUATION CRITERIA
Corrosivity potential of the test item was predicted form the relative mean tissue viabilities compard to the negative control tissues concurrently treated with aqua dest. The substance is classified corrosive to skin if the tissue relative viability after 3 min of exposure is decreased below 50%. In addition, those test items classified as non-corrosive after 3 min (viability > 50%) are classified as corrosive if the relative mean tissue viability after 60 min treatment is decreased below 15% compared to the concurrent negative control tissue.
Results and discussion
In vivo
Resultsopen allclose all
- Irritation parameter:
- other: cell viability (% of negative control)
- Basis:
- other: negative control (aqua dest.)
- Time point:
- other: 15 min
- Score:
- 100
- Irritation parameter:
- other: cell viability (% of negative control)
- Basis:
- other: test material
- Time point:
- other: 3 min
- Score:
- 90
- Irritation parameter:
- other: cell viability (% of negative control)
- Basis:
- other: test material
- Time point:
- other: 60 min
- Score:
- 114
- Irritation parameter:
- other: cell viability (% of negative control)
- Basis:
- other: positive control (8 N KOH)
- Time point:
- other: 3 min
- Score:
- 17
- Irritation parameter:
- other: cell viability (% of negative control)
- Basis:
- other: positive control (8 N KOH)
- Time point:
- other: 60 min
- Score:
- 9
- Irritant / corrosive response data:
- The cell viability after 3 min and 60 min exposure was greater than 50% and 15%, respectively.
- Other effects:
- No further effects were reported.
Any other information on results incl. tables
Table 1. Summary of results.
Total OD550of 2 replicate tissues |
Mean relative tissue viabilitiy[%] |
SD tissue viability [%] |
|
3 min |
|
|
|
Negative Control PBS |
2.112* |
100 |
8.3*** |
Test Item |
1.896 |
90 |
14.9*** |
Positive Control 5% SDS |
0.355 |
17** |
15.1*** |
60 min |
|
|
|
Negative Control PBS |
2.174* |
100 |
0.8*** |
Test Item |
2.479 |
114 |
27.7*** |
Positive Control 5% SDS |
0.204 |
9 |
18.7*** |
*: mean OD550 > 0.8 of the negative control. Therefore, the validity criteria are fulfilled.
**: mean relative tissue viability of the 3 min positive control ≤ 30%. Therefore the validity criteria are fulfilled.
***: inter tissue viability difference < 30% for all dose groups. Therefore, the validity criteria are fulfilled.
OD: Absorption at 550 nm
SD: Standard deviation
Applicant's summary and conclusion
- Interpretation of results:
- other: non-corrosive
- Remarks:
- Criteria used for interpretation of results: EU
- Conclusions:
- According to Regulation (EC) No. 1272/2008, a substance can be considered corrosive (Skin Corrosive Cat.1A) based on a positive result in the human epidermis model test. Negative in vitro corrosivity responses are not conclusive with respect to non-classification or classification as irritant and shall therefore be subject to further evaluation.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.

EU Privacy Disclaimer
This website uses cookies to ensure you get the best experience on our websites.