First-aid measures

Inhalation : Remove to fresh air. If rapid recovery does not occur, transport to nearest medical facility for additional treatment.

Skin Contact :       Remove contaminated clothing. Flush exposed area with water and follow by washing with soap if available.

Eye Contact : Flush eye with copious quantities of water. If persistent irritation occurs, obtain medical attention.

Ingestion : If swallowed, do not induce vomiting: transport to nearest medical facility for additional treatment. If vomiting occurs spontaneously, keep head below hips to prevent aspiration. If any of the following delayed signs and symptoms appear within the next 6 hours, transport to the nearest medical facility:  fever greater than 101° F (37° C), shortness of breath, chest congestion or continued coughing or wheezing.

Advice to Physician : Potential for chemical pneumonitis. Consider: gastric lavage with protected airway, administration of activated charcoal. Call a doctor or poison control center for guidance. Potential for cardiac sensitisation, particularly in abuse situations. Hypoxia or negative inotropes may enhance these effects. Consider: oxygen therapy.

Fire-fighting measures

Carbon monoxide may be evolved if incomplete combustion occurs. Will float and can be reignited on surface water. The vapour is heavier than air, spreads along the ground and distant ignition is possible.

Foam, water spray or fog. Dry chemical powder, carbon dioxide, sand or earth may be used for small fires only. Do not discharge extinguishing waters into the aquatic environment.

Do not use water in a jet.

Wear full protective clothing and self-contained breathing apparatus.

Keep adjacent containers cool by spraying with water.

Accidental release measures

Protective measures : Avoid contact with spilled or released material. Immediately remove all contaminated clothing. Shut off leaks, if possible without personal risks. Remove all possible sources of ignition in the surrounding area. Use appropriate containment (of product and fire fighting water) to avoid environmental contamination. Prevent from spreading or entering drains, ditches or rivers by using sand, earth, or other appropriate barriers. Attempt to disperse the vapour or to direct its flow to a safe location for example by using fog sprays. Take precautionary measures against static discharge. Ensure electrical continuity by bonding and grounding (earthing) all equipment. Monitor area with combustible gas indicator.

Clean Up Methods : For small liquid spills (< 1 drum), transfer by mechanical means to a labelled, sealable container for product recovery or safe disposal. Allow residues to evaporate or soak up with an appropriate absorbent material and dispose of safely. Remove contaminated soil and dispose of safely.

For large liquid spills (> 1 drum), transfer by mechanical means such as vacuum truck to a salvage tank for recovery or safe disposal. Do not flush away residues with water. Retain as contaminated waste. Allow residues to evaporate or soak up with an appropriate absorbent material and dispose of safely. Remove contaminated soil and dispose of safely.

Handling and storage

Handling : Extinguish any naked flames. Do not smoke. Remove ignition sources. Avoid sparks. Avoid contact with skin, eyes, and clothing. Electrostatic charges may be generated during pumping. Electrostatic discharge may cause fire. Ensure electrical continuity by bonding and grounding (earthing) all equipment. Restrict line velocity during pumping in order to avoid generation of electrostatic discharge. Avoid splash filling. Do NOT use compressed air for filling, discharging, or handling operations.

Storage : Must be stored in a diked (bunded) well-ventilated area, away from sunlight, ignition sources and other sources of heat. Keep away from aerosols, flammables, oxidizing agents, corrosives and from other flammable products which are not harmful or toxic to man or to the environment. Storage Temperature: Ambient.

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
1268
Shippingopen allclose all
Labels:
Danger Label (Primary Risk): 3
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

UN number:
1268
Shippingopen allclose all
Labels:
Danger Label (Primary risk): 3
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
1268
Shipping information
Proper shipping name and description:
PETROLEUM DISTILLATES, N.O.S. ()
Chemical name:
PETROLEUM DISTILLATES, N.O.S. ()
Labels:
Danger Label (Primary Risk): 3
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
UN 1268
Shipping information
Proper shipping name and description:
PETROLEUM DISTILLATES, N.O.S. ()
Chemical name:
PETROLEUM DISTILLATES, N.O.S. ()
Labels:
Hazard Label: 3
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Disposal considerations