Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
16 March 2010 - 14 June 2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.16 (Relative Self-Ignition Temperature for Solids)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Key result
Remarks on result:
other: exothermic effect at 260°C

An exothermic effect of the test substance by self-heating was observed at an oven temperature of 260°C. During this effect the test substance reached a temperature of 303°C. According to the guideline, a test substance is self-ignitable when the sample temperature reaches 400°C by self-heating. Based on this the test substance is considered ‘not self-ignitable’.

After the experiment, the test substance had turned into a black/brown/white residue and was collected in a container that was placed below the cube. Residue was also found in the cube. It indicated that the test substance had been expanded, decomposed and/or reacted during the experiment.

Conclusions:
The self-ignition temperature of MIZULAN FL-80 was determined using a temperature programmed laboratory oven, a stainless steel wire mesh cube, NiCr/NiAl thermocouples and a temperature recording device. Based on the results obtained the test substance is considered ‘not self-ignitable’.

Description of key information

The self-ignition temperature of MIZULAN FL-80 was determined using a temperature programmed laboratory oven, a stainless steel wire mesh cube, NiCr/NiAl thermocouples and a temperature recording device. Based on the results obtained the test substance is considered ‘not self-ignitable’.

Key value for chemical safety assessment

Additional information

Based on the results obtained the test substance is considered ‘not self-ignitable’.