Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
from 17 June 1988 to 20 June 1988
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1988
Report date:
1988

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
not specified
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
not specified
GLP compliance:
yes
Type of method:
gas saturation method

Test material

Constituent 1
Chemical structure
Reference substance name:
Propazine
EC Number:
205-359-9
EC Name:
Propazine
Cas Number:
139-40-2
Molecular formula:
C9H16ClN5
IUPAC Name:
6-chloro-N2,N4-bis(propan-2-yl)-1,3,5-triazine-2,4-diamine
Details on test material:
Product name: propazine
CAS #: 139-40-2
Mol. weight (g): 229.71
Mol. formula: C9H16ClN5
Identification: 129/103
Batch: G 30028
Purity: 99.6%

Results and discussion

Vapour pressure
Temp.:
25 °C
Vapour pressure:
0 Pa
Remarks on result:
other: from fit of measurements between 32.5 and 139°C.
Transition / decomposition
Transition / decomposition:
no
Transition temp.:
>= 32.5 - <= 139 °C

Any other information on results incl. tables

All of the selected good vapor pressure measurement points and temperatures are indicated in the vapor pressure report. This report contains also the calibration equation and plot used for the evaluation of the raw data. Included are furthermore the vapor pressure plot and calculated (interand extrapolated) vapor pressures for a number of fixed temperatures.

None problems were encountered during the measurments.

Applicant's summary and conclusion