Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
comparable to guideline study with acceptable restrictions
Qualifier:
according to guideline
Guideline:
ISO No., other: DIN 51758
GLP compliance:
not specified
Type of method:
closed cup
Key result
Flash point:
116 °C
Atm. press.:
1 atm
Interpretation of results:
GHS criteria not met
Conclusions:
The flash point (closed cup) was determined to be at least 116 °C at 101325 Pa.
Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
supporting study
Study period:
2012
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions
Qualifier:
equivalent or similar to guideline
Guideline:
ISO No., other: ASTM D93
GLP compliance:
no
Type of method:
closed cup
Flash point:
118 °C
Atm. press.:
1 atm

Description of key information

The flash point (closed cup) was determined to be at least 116 °C on two independent determinations.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
116 °C

Additional information