Registration Dossier

Diss Factsheets

Ecotoxicological information

Endpoint summary

Administrative data

Description of key information

Additional information

Testing for toxicity to terrestrial organisms is not considered necessary because:

- The substance hydrolyses rapidly and its hydrolysis product has a Log Kow < 3, therefore, partitioning to the terrestrial compartment is expected to be minimal.

- The substance is used under highly controlled conditions and, therefore, exposure of soil is low.

- PNECsoil has been calculated from PNECfreshwater on the basis of the equilibrium partitioning method; the risk characterisation ratio (RCR) based on PNECsoil is <1.