Registration Dossier

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
yes (incl. QA statement)
Key result
Test procedure:
burning time (test type not further specified)
Remarks:
or specified in description of method (migrated information)
Burning time:
> 240 s

Preliminary test: Burning time > 4 min, no metal powder. Therefore, the preliminary screening test is negative.

Main test: Omitted due to result of preliminary test.

Interpretation of the results: The test substance is not considered highly flammable.

Interpretation of results:
not classified based on GHS criteria
Conclusions:
Based on the results, the test substance can be considered as not flammable.
Executive summary:

In a study conducted according to EU method A.10, the burning time of the pile in a preliminary test was > 4 minutes. Thus, it was not necessary to conduct a main test and the test item maleic anhydride can be considered as a not flammable solid.

Description of key information

In a study conducted according to EU method A.10, the burning time of the pile in a preliminary test was > 4 minutes. Thus, it was not necessary to conduct a main test and the test item maleic anhydride can be considered as a not flammable solid.

Key value for chemical safety assessment

Flammability:
non flammable

Additional information

Justification for classification or non-classification