Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2009
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The study was performed according to guideline

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
2009
Report date:
2009

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
Deviations:
no
GLP compliance:
no
Remarks:
ISO 9001/2000 Certified
Type of method:
non-equilibrium method closed cup

Test material

Constituent 1
Chemical structure
Reference substance name:
Phosphorodithioic acid, mixed O,O-bis(2-ethylhexyl and iso-Pr) esters, zinc salts
EC Number:
272-723-1
EC Name:
Phosphorodithioic acid, mixed O,O-bis(2-ethylhexyl and iso-Pr) esters, zinc salts
Cas Number:
68909-93-3
Molecular formula:
Too complex
IUPAC Name:
Phosphorodithioic acid, mixed O,O-bis(2-ethylhexyl and iso-Pr) esters, zinc salts

Results and discussion

Flash point
Flash point:
193 °C
Atm. press.:
760 mm Hg

Applicant's summary and conclusion

Conclusions:
The flash point of the test substance is 193 deg. C at 760 mmHg.
Executive summary:

The test material flash point is 193 deg. C at 760 mmHg as determined by the Pensky-Martens Closed cup (PMCC) Tester