Registration Dossier

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

MMD= 69 µm

D10= 15 µm

D90= 320 µm

Additional information

The measurement was carried out by laser diffraction method according to ISO 13320.

In addition, the values [vol%] for the particle size fractions are as follows:

<4 µm= 2%

<10 µm= 6.4%

<100 µm= 62%