EC number: 244-289-3 | CAS number: 21245-02-3
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Toxicity to microorganisms
Administrative data
Link to relevant study record(s)
- Endpoint:
- activated sludge respiration inhibition testing
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 11 August 2016 to 12 August 2016
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test (Carbon and Ammonium Oxidation))
- Version / remarks:
- 2010
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Analytical monitoring:
- no
- Vehicle:
- no
- Test organisms (species):
- activated sludge of a predominantly domestic sewage
- Details on inoculum:
- - Name and location of sewage treatment plant where inoculum was collected: Aeration stage of the Severn Trent Water Plc sewage treatment plant at Loughborough, Leicestershire, UK which treats predominantly domestic sewage.
- Preparation of inoculum for exposure: The activated sewage sludge sample was maintained on continuous aeration in the laboratory at a temperature of approximately 21 °C and was used on the day of collection. The pH of the sample was 7.7. Determination of the suspended solids level of the activated sewage sludge was carried out by filtering a sample (100 mL) of the activated sewage sludge by suction through a pre-weighed GF/A filter paper (rinsed three times with 20 mL deionized reverse osmosis water prior to drying in an oven) using a Buchner funnel which was then rinsed 3 times with 10 mL of deionised reverse osmosis water and filtration continued for 3 minutes. The filter paper was then dried in an oven at approximately 105 °C for at least one hour and allowed to cool before weighing. This process was repeated until a constant weight was attained.
- Initial biomass concentration: The suspended solids concentration was equal to 3.0 g/L - Test type:
- static
- Water media type:
- freshwater
- Limit test:
- no
- Total exposure duration:
- 3 h
- Test temperature:
- 20 to 21 °C
- pH:
- 7.8 to 8.0 after adjustment
- Dissolved oxygen:
- The dissolved oxygen concentrations after 30 minutes contact time in all vessels were above 60 to 70 % of the dissolved oxygen saturation level of 8.9 mg O2/L.
- Nominal and measured concentrations:
- - Nominal concentrations: 10, 100 and 1000 mg/L
- Details on test conditions:
- TEST SYSTEM
- Test vessel: Conical flask
- Type: closed
- Material, size, headspace, fill volume: Final volume of 500 mL
- Aeration: Yes; at the time of preparation of each flask, the mixture was aerated with clean, oil-free compressed air via narrow bore glass tubes at a rate of 0.5 to 1.0 L/minute.
- No. of vessels per concentration (replicates): 3 (top dose) and 2 (low and intermediate dose)
- No. of vessels per control (replicates): 4
- No. of vessels per positive control (replicates): 1 per concentration level (3.2, 10 and 32 mg/L)
- Sludge concentration (weight of dry solids per volume): 3.0 g/L
TEST MEDIUM / WATER PARAMETERS
- Source/preparation of dilution water: Deionised reverse osmosis water containing less than 1 mg/L dissolved organic carbon (DOC)
- Synthetic sewage: 16 g peptone, 11 g meat extract, 3 g urea, 0.7 g NaCl, 0.4 g CaCl2.2H2O, 0.2 g MgSO4.7H2O and 2.8 g K2HPO4 dissolved in a final volume of 1 litre of water with the aid of ultrasonication. The pH of the synthetic sewage stock was 7.3.
OTHER TEST CONDITIONS
- Adjustment of pH: Yes, adjusted to between pH 7 and 8 if necessary
- Photoperiod: Continuous
- Light intensity: Normal laboratory lighting
- Details on termination of incubation: As each vessel reached 3 hours contact time an aliquot was removed from the conical flask and poured into the measuring vessel (250 mL darkened glass Biological Oxygen Demand (BOD) bottle) and the rate of respiration measured.
EFFECT PARAMETERS MEASURED (with observation intervals if applicable):
Observations were made on the test preparations throughout the test period. Observations of the test material vessels at 0 hours were made prior to addition of activated sewage sludge. The pH of test preparations was measured at the test start (i.e. after the addition of activated sludge) and at the end of the 3-hour incubation period. The oxygen concentrations in all vessels were measured after 30 minutes contact time.
The rate of respiration measured using a Yellow Springs dissolved oxygen meter fitted with a BOD probe. The contents of the measuring vessel were stirred constantly by magnetic stirrer. The rate of respiration for each flask was measured over the linear portion of the oxygen consumption trace (where possible between 7 and 2 mg O2/L). In the case of rapid oxygen consumption, measurements may have been outside this range but the oxygen consumption was always within the linear portion of the respiration curve. In the case of low oxygen consumption, the rate was determined over an approximate 10 minute period.
TEST CONCENTRATIONS
- Spacing factor for test concentrations: 10
- Range finding study: Yes
- Test concentrations: 10, 100 and 1000 mg/L
- Results used to determine the conditions for the definitive study: No statistically significant toxic effects were shown at any of the test concentrations employed. It was therefore considered justifiable not to perform a definitive test. - Reference substance (positive control):
- yes
- Remarks:
- 3,5-dichlorophenol
- Key result
- Duration:
- 3 h
- Dose descriptor:
- NOEC
- Effect conc.:
- >= 1 000 mg/L
- Nominal / measured:
- nominal
- Conc. based on:
- test mat.
- Basis for effect:
- inhibition of total respiration
- Key result
- Duration:
- 3 h
- Dose descriptor:
- EC50
- Effect conc.:
- > 1 000 mg/L
- Nominal / measured:
- nominal
- Conc. based on:
- test mat.
- Basis for effect:
- inhibition of total respiration
- Details on results:
- Oxygen consumption rates and percentage inhibition values for the control, test and reference materials after 3 hours contact time are given in Table 1.
No statistically significant toxic effects were shown at any of the test concentrations employed. It was therefore considered justifiable not to perform a definitive test.
It was considered unnecessary and unrealistic to test at concentrations in excess of 1000 mg/L.
VALIDATION CRITERIA
The results of the study are considered valid if:
- the EC50 (3-hour contact time) for 3,5-dichlorophenol lies within the range 2 to 25 mg/L for total respiration.
- the specific respiration rate of the blank controls is not less than 20 mg oxygen per gram dry weight of sludge per hour for total respiration.
- the coefficient of variation of oxygen uptake rate in control replicates is not more than 30 % at the end of the test.
The coefficient of variation of oxygen uptake in the control vessels was 1.75 % and the specific respiration rate of the controls was 24.37 mg oxygen per gram dry weight of sludge per hour. The validation criteria have therefore been satisfied. The validation criterion for the reference item EC50 value was also satisfied. - Results with reference substance (positive control):
- The validation criterion for the reference item EC50 value was satisfied in this study. The EC50 was determined to be 8.4 mg/L with 95 % confidence limits of 6.7 to 11 mg/L.
- Reported statistics and error estimates:
- ECX and NOEC
The percentage inhibition values were plotted against concentration for the reference material only, a line fitted using the Xlfit software package (IDBS) and the EC10, EC20, EC50 and EC80 values determined from the equation for the fitted line. The EC10, EC20, EC50 and EC80 values for the test material were determined by inspection of the inhibition of respiration rate data. 95 % confidence limits were calculated for the reference material EC50 value using the method of Litchfield and Wilcoxon (Litchfield and Wilcoxon, 1949).
In order to determine the NOEC, one way analysis of variance incorporating Bartlett's test for homogeneity of variance and Dunnett's multiple comparison procedure for comparing several treatments with a control was carried out on the oxygen consumption data for the range-finding test after 3 hours for the control and all test concentrations to determine any statistically significant differences between the test and control groups. All statistical analyses were performed using the SAS computer software package (SAS, 1999 - 2001). - Validity criteria fulfilled:
- yes
- Conclusions:
- Under the conditions of this study the 3-hour EC50 value was greater than 1000 mg/L. The No Observed Effect Concentration (NOEC) was 1000 mg/L.
- Executive summary:
The toxicity of the test material to activated sludge was determined in accordance with the standardised guideline OECD 209 under GLP conditions using a respiration inhibition test.
Activated sewage sludge was exposed to an aqueous dispersion of the test material at concentrations of 10, 100 and 1000 mg/L (3 replicates of the 1000 mg/L test concentration) for a period of 3 hours at temperatures of between 20 and 21 °C with the addition of synthetic sewage as a respiratory substrate.
The rate of respiration was determined after 3 hours of contact time and compared to data for the control and a reference material, 3,5-dichlorophenol.
No statistically significant toxic effects were shown at any of the test concentrations employed. It was therefore considered justifiable not to perform a definitive test. It was considered unnecessary and unrealistic to test at concentrations in excess of 1000 mg/L. The reference material gave a 3-hour EC50 value of 8.4 mg/L with 95 % confidence limits of 6.7 to 11 mg/L.
Under the conditions of this study the 3-hour EC50 value was greater than 1000 mg/L. The No Observed Effect Concentration (NOEC) was 1000 mg/L.
Reference
Table 1 Oxygen Consumption Rates and Percentage Inhibition Values after 3 Hours of Contact Time
Nominal Concentration (mg/L) |
Initial O2 Reading (mg O2/L) |
Measurement Period (minutes) |
Final O2 Reading (mg O2/L) |
O2 Consumption Rates (mg O2/L/hour) |
% Inhibition |
|
Control |
R1 |
4.3 |
4 |
1.9 |
36.00 |
- |
R2 |
5.0 |
5 |
1.9 |
37.20 |
- |
|
R3 |
5.2 |
5 |
2.2 |
36.00 |
- |
|
R4 |
5.6 |
6 |
1.9 |
37.00 |
- |
|
Test material |
10 |
4.2 |
4 |
1.6 |
39.00 |
[7] |
100 |
4.0 |
3 |
2.1 |
38.00 |
[4] |
|
1000 R1 |
4.5 |
4 |
2.0 |
37.50 |
[3] |
|
1000 R2 |
5.2 |
6 |
1.6 |
36.00 |
2 |
|
1000 R3 |
4.2 |
4 |
1.8 |
36.00 |
2 |
|
Positive control |
3.2 |
5.7 |
8 |
1.8 |
29.25 |
20 |
10 |
7.1 |
10 |
4.5 |
15.60 |
57 |
|
32 |
8.1 |
10 |
7.4 |
4.20 |
89 |
[ ] = Increase in respiration rate as compared to the controls
Description of key information
The toxicity of the test material to activated sludge was determined in accordance with the standardised guideline OECD 209 under GLP conditions using a respiration inhibition test. The study was awarded a reliability score of 1 in accordance with the criteria set forth by Klimisch et al. (1997).
Activated sewage sludge was exposed to an aqueous dispersion of the test material at concentrations of 10, 100 and 1000 mg/L (3 replicates of the 1000 mg/L test concentration) for a period of 3 hours at temperatures of between 20 and 21 °C with the addition of synthetic sewage as a respiratory substrate.
The rate of respiration was determined after 3 hours of contact time and compared to data for the control and a reference material, 3,5-dichlorophenol.
No statistically significant toxic effects were shown at any of the test concentrations employed. It was therefore considered justifiable not to perform a definitive test. It was considered unnecessary and unrealistic to test at concentrations in excess of 1000 mg/L. The reference material gave a 3-hour EC50 value of 8.4 mg/L with 95 % confidence limits of 6.7 to 11 mg/L.
Under the conditions of this study the 3-hour EC50 value was greater than 1000 mg/L. The No Observed Effect Concentration (NOEC) was 1000 mg/L.
Key value for chemical safety assessment
- EC10 or NOEC for microorganisms:
- 1 000 mg/L
Additional information
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.