Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 247-465-8 | CAS number: 26115-70-8
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Guidance on Safe Use
Administrative data
First-aid measures
Description of first aid measures
Remove contaminated or saturated clothing.
Inhalation
If aerosol or mists are formed:
Move victims into fresh air.
If symptoms persist, call a physician.
Skin contact
Wash off with soap and water.
Eye contact
Rinse thoroughly with plenty of water keeping eyelid open.
In case of persistent discomfort: Consult an ophthalmologist.
Ingestion
Have the mouth rinsed with water.
After absorbing large amounts of substance / In case of discomfort: Supply with medical care.
Most important symptoms and effects, both acute and delayed
Symptoms
None known
Hazards
None known
Indication of any immediate medical attention and special treatment needed
Specific therapy/antidote treatment: none known
After absorbing large amounts of substance:
administration of activated charcoal.
Acceleration of gastrointestinal passage
Fire-fighting measures
Extinguishing media
Suitable extinguishing media:
Water spray, foam, CO2, dry powder.
Special hazards arising from the substance or mixture
Hazard-determining flue gases might develop in case of fire:
nitrogen oxides (NOx)
Advice for firefighters
Water used to extinguish fire should not enter drainage systems, soil or stretches of water.
Ensure there are sufficient retaining facilities for water used to extinguish fire.
Fire residues and contaminated fire extinguishing water must be disposed of in accordance with local regulations.
In case of fire: wear a self contained respiratory apparatus
Accidental release measures
Personal precautions, protective equipment and emergency procedures
Wear personal protective equipment.
Observe the rules usually applicable when handling chemicals.
Avoid contact with skin and eyes.
Environmental precautions
Do not allow entrance in sewage water, soil stretches of water, groundwater, drainage systems.
Methods and material for containment and cleaning up
Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust).
Fill into marked, sealable containers.
To be disposed of in compliance with existing regulations.
Suitable binder: sand (for damming up)
Handling and storage
Precautions for safe handling
Avoid contact with skin and eyes.
Conditions for safe storage, including any incompatibilities
Advice on protection against fire and explosion
Normal measures for preventive fire protection.
Storage
Keep container tightly closed.
Suitable materials stainless steel
Transport information
Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all
Marine transport (UN RTDG/IMDG)
Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all
Exposure controls / personal protection
Control parameters
Other information
No substance-specific limiting value being known.
Exposure controls
Engineering measures
Application, processing: Provide good ventilation or extraction.
Personal protective equipment
Respiratory protection
In case of dusts/vapours/aerosols being formed or if the limit values like TLV are exceeded:
use respiratory equipment with suitable filter (filter type ABEK) or wear a self contained respiratory apparatus
Use only respiratory protection equipment with CE-symbol including four digit test number.
The filter class for the respirator must be suitable for the maximum expected contaminant concentration (gas/vapour/aerosol/particulates) that may arise when handling the product. If this concentration is exceeded, self-contained breathing apparatus must be used.
Note time limit for wearing respiratory protective equipment.
Hand protection
Glove material for example, butyl-rubber
Material thickness 0,5 mm
Break through time >= 480 min
Glove material for example, Fluorinated rubber (Viton)
Material thickness 0,4 mm
Break through time >= 480 min
Selection of protective gloves to meet the requirements of specific workplaces.
Suitability for specific workplaces should be clarified with protective glove manufacturers.
The information is based on our own tests, references from the literature and information from glove manufacturers, or derived by analogy with similar materials.
Please observe that the daily duration of usage of a chemical protective glove is in practice far shorter due to the many influencing factors (e.g. temperature, mechanical strain on the glove material) than the permeation time determined acc. EN 374.
Eye protection
Safety glasses
Hygiene measures
When using, do not eat, drink or smoke. Wash face and/or hands before break and end of work.
Remove immediately all contaminated clothing.
Wash contaminated clothing before re-use.
Protective measures
Handle in accordance with good industrial hygiene and safety practice.
The personal protective equipment used must meet the requirements of directive 89/686/EEC and amendments (CE certification).
If workplace exposure limits are exceeded and/or larger amounts are released (leakage, spilling, dust) the indicated respiratory protection should be used.
If there is the possibility of skin/eye contact, the indicated hand/eye/body protection should be used.
Do not breathe in vapours or aerosols.
Avoid contact with skin and eyes.
Stability and reactivity
Reactivity
No dangerous reaction known under conditions of normal use
Chemical stability
Stable under recommended storage conditions
Possibility of hazardous reactions
Possibility of hazardous reactions None known.
Conditions to avoid
humidity10.5. Incompatible materials
None known
Hazardous decomposition products
Methanol in case of hydrolysis
Disposal considerations
Waste treatment methods
Product
With respect to local regulations, e.g. dispose of to waste incineration plant
Uncleaned packaging
Do not reuse empty containers and dispose of in accordance with the regulations issued by the appropriate local authorities.
If there is product residue in the emptied container, follow directions for handling on the container's label.
Incorrect disposal or reuse of this container is illegal and can be dangerous.
Other countries: observe the national regulations.
Waste Key Number
No waste key number as per the European Waste Types List can be assigned to this product, since such classification is based on the (as yet undetermined) use to which the product is put by the consumer.
The waste key number must be determined as per the European Waste Types List (decision on EU Waste Types List 2000/532/EC) in cooperation with the disposal firm / producing firm / official authority.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.