Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From January 10,2017 to February 03,2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Specific details on test material used for the study:
Batch number: VE00463145
Purity: 99.9%
Expiration date: April 06, 2018
Key result
Flash point:
192.5 °C
Atm. press.:
101 325 Pa
Interpretation of results:
GHS criteria not met
Conclusions:
The results of the main tests are:
First determination: Flash point, corrected for atmospheric pressure: 193.0°C
Second determination: Flash point, corrected for atmospheric pressure: 192.0°C
The results of the two tests were averaged and rounded off to the nearest 0.5°C to obtain the final flash point value:
Flash point SINODOR CQ: 192.5 °C.
Executive summary:

The flash point of SINODOR CQ was determined by the Pensky-Martens method according to the ISO 2719. The result is: 192.5°C.

Description of key information

The flash point of SINODOR CQ was determined by the Pensky-Martens method according to the ISO 2719 and under GLP. The result is: 192.5°C so SINODOR CQ is not classified as flammable liquid.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
192.5 °C

Additional information