Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 946-682-1 | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Flash point
Administrative data
Link to relevant study record(s)
- Endpoint:
- flash point of flammable liquids
- Type of information:
- experimental study
- Adequacy of study:
- supporting study
- Study period:
- November 20th 2018
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- guideline study without detailed documentation
- Justification for type of information:
- The study was conducted according to an ASTM standard method. The substance is considered to be adequately characterised. Therefore full validation applies.
- Qualifier:
- according to guideline
- Guideline:
- other: ASTM D6450-16
- GLP compliance:
- no
- Type of method:
- closed cup
- Flash point apparatus:
- other: Miniflash Closed-cup Flash Point Tester
- Flash point:
- > 200 °C
- Remarks on result:
- other: Pressure not specified
- Interpretation of results:
- GHS criteria not met
- Conclusions:
- The flash point of test item was measured according to ASTM D6450 using closed cup method.
Measurement was performed in duplicate and flash point was determined to be >200°C.
Test item should not be classified as flammable liquid according to Regulation (EC)1272/2008 (CLP criteria). - Executive summary:
The flash point of test item was measured according to ASTM D6450 using closed cup method.
Measurement was performed in duplicate and flash point was determined to be >200°C.
Test item should not be classified as flammable liquid according to Regulation (EC)1272/2008 (CLP criteria).
- Endpoint:
- flash point of flammable liquids
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 2018-12-03 to 2019-03-28
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Justification for type of information:
- The study was conducted according to an ASTM standard method and under GLP. The substance is considered to be adequately characterised. Therefore full validation applies.
- Qualifier:
- according to guideline
- Guideline:
- other: ASTM D6450 Standard Test Method for Flash Point by Continuously Closed Cup Tester
- Principles of method if other than guideline:
- Not applicable
- GLP compliance:
- yes
- Type of method:
- closed cup
- Flash point apparatus:
- other: SCBS303 Closed cup flash point tester
- Key result
- Flash point:
- 201 °C
- Atm. press.:
- 101.3 kPa
- Interpretation of results:
- GHS criteria not met
- Conclusions:
- Flash point of test item was measured according to ASTM D6450 using a closed cup tester.
Flash point of test item was measured to be 201.0°C at 101.3kPa (corrected value of duplicate measurements).
Test item should NOT be classified as flammable liquid. - Executive summary:
Flash point of test item was measured according to ASTM D6450 using a closed cup tester.
Flash point of test item was measured to be 201.0°C at 101.3kPa (corrected value of duplicate measurements).
Test item should NOT be classified as flammable liquid.
Referenceopen allclose all
The determination of flash point was performed in duplicate
No. |
Result |
1 |
>200 °C |
2 |
>200 °C |
Average |
>200 °C |
Results of the apparatus check:
Atmospheric pressure: 102.9 kPa (in the range of 98.0 -104.7 kPa)
Flash point of anisole was 47.2°C (criteria 43.9 +6°C), which passed the check.
Results of test item:
Results of two individual tests were 200.2°C (103.0kPa) and 202.3°C (103.1kPa). The average value of two results was 201.3°C.
According to the equation (presented in section method), flash point of test item was 201.0°C at standrad atmosphere pressure (101.3 kPa).
Description of key information
The flash point of test item was measured according to ASTM D6450 using closed cup method in two studies.
Measurement was performed in duplicate and flash point was determined to be >200°C.
The test item is NOT classified as flammable liquid according to Regulation (EC) 1272/2008 (CLP regulation).
Key value for chemical safety assessment
- Flash point at 101 325 Pa:
- 201 °C
Additional information
Fully reliable experimental studies, conducted according to ASTM D6450 (and one according to GLP) method is available.
It is considered as a key study, and the result is retained as key data.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.