Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
June 2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP study performed according to OECD guideline 117 and EU Method A.8

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.8 (Partition Coefficient)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
Food and Consumer Product Safety Authority (VWA), The Netherlands
Type of method:
HPLC method
Partition coefficient type:
octanol-water

Test material

Constituent 1
Chemical structure
Reference substance name:
2-chloropropene
EC Number:
209-187-5
EC Name:
2-chloropropene
Cas Number:
557-98-2
Molecular formula:
C3H5Cl
IUPAC Name:
2-chloroprop-1-ene
Constituent 2
Chemical structure
Reference substance name:
2-chloropropane
EC Number:
200-858-8
EC Name:
2-chloropropane
Cas Number:
75-29-6
Molecular formula:
C3H7Cl
IUPAC Name:
2-chloropropane
Constituent 3
Reference substance name:
1-chloropropene
EC Number:
209-675-8
EC Name:
1-chloropropene
Cas Number:
590-21-6
IUPAC Name:
1-chloroprop-1-ene
Details on test material:
Identification Reaction mass containing mainly 2-chloropropene
Molecular formula C3H5Cl
Molecular weight 76.53
CAS Number 557-98-2
Description Clear light yellow to brown liquid (determined at NOTOX)
Batch RBA100301A
Purity Minimum 60.0%
Test substance storage In refrigerator (2-8°C) in the dark
Stability under storage conditions Stable
Expiry date 08 March 2011 (allocated by NOTOX, 1 year after receipt of the test substance)

Study design

Analytical method:
high-performance liquid chromatography

Results and discussion

Partition coefficient
Type:
log Pow
Partition coefficient:
2.1

Any other information on results incl. tables

Calculation method:

Calculation of the Pow

The Powof the test substance was calculated to be 27.5(log Pow1.44) using the Rekker calculation method.

 

Calculation of the pKa

No pKavalues for acidic and basic groups in the molecular structure of the test substance in the logarithm range of 1 – 14 were calculated.

 

HPLC Method

In the HPLC chromatogram of the test substance solution, one large test substance peak and two small peaks obtained from impurities were observed.

 

The results of the HPLC method are given in the Table10. The calibration curve of the log k’ of the reference substances as function of log Pow showed that the equation of the regression line was: log k’ = 0.596´log Pow- 0.516 (r = 0.9992, n = 12).

 

Table10         Powat neutral pH

Substance

tr,1
[min]

tr,2
[min]

mean tr
(n=2)

log Pow

Pow

Area
%

 

 

 

 

 

 

 

Formamide (t0)

1.124

1.122

1.123

 

 

 

 

 

 

 

 

 

 

Ethylmethylketone

1.666

1.662

 

0.3

 

 

Benzylalcohol

2.555

2.543

 

1.1

 

 

Nitrobenzene

5.729

5.695

 

1.9

 

 

Toluene

16.586

16.520

 

2.7

 

 

Bromobenzene

21.531

21.431

 

3.0

 

 

1,4-Dichlorobenzene

36.589

36.373

 

3.4

 

 

 

 

 

 

 

 

 

Impurity I

4.810

4.799

4.805

1.7

5.4´101

0.71

Impurity II

6.653

6.630

6.642

2.0

1.1´102

0.99

Test substance

7.615

7.598

7.607

2.1

1.4´102

98.3

 

 

 

 

 

 

 

 

Applicant's summary and conclusion

Executive summary:

The HPLC method was chosen for the determination of the partition coefficient of the reaction mass containing mainly 2-chloropropene.

 

The Powand log Powvalue of the test substance and impurities with a peak area of < 1% was:

 

 

Pow

log Pow

Area
%

 

 

 

 

Test substance

1.4´102

2.1

98.3

Impurity I

5.4´101

1.7

0.71

Impurity II

1.1´102

2.0

0.99